Share:


M25P20-VMN6P

Specifications

SKU: 11250034

BUY M25P20-VMN6P https://www.utsource.net/itm/p/11250034.html

Parameter Symbol Min Typ Max Unit Notes
Supply Voltage VCC 2.7 - 3.6 V
Standby Current ICC(STANDBY) - 1 2 μA
Active Current ICC(ACTIVE) - 4 8 mA
Programming Current IPROG - 1 5 mA
Erase Time (Sector) tSECTOR_ERASE - 200 400 ms
Write Time (Byte) tBYTE_WRITE - 1 5 ms
Read Time (Byte) tBYTE_READ - 25 50 ns
Page Program Time tPAGE_PROGRAM - 1 5 ms
Data Retention - - 20 - Years
Operating Temperature TOP -40 - 85 °C
Storage Temperature TSTORAGE -65 - 150 °C
Package Type - - - - SOIC-8, TSSOP-8

Instructions for M25P20-VMN6P

  1. Power Supply:

    • Ensure the supply voltage (VCC) is within the range of 2.7V to 3.6V.
    • The device should be powered down properly to avoid data corruption.
  2. Standby Mode:

    • To enter standby mode, set the chip select (CS) pin high.
    • The typical standby current is 1 μA, with a maximum of 2 μA.
  3. Active Mode:

    • To enter active mode, set the chip select (CS) pin low.
    • The typical active current is 4 mA, with a maximum of 8 mA.
  4. Programming:

    • Use the WRITE ENABLE (WREN) command before programming or erasing.
    • The programming current (IPROG) should be between 1 mA and 5 mA.
    • The page program time is typically 1 ms, with a maximum of 5 ms.
  5. Erase Operations:

    • Sector erase operations take approximately 200 ms to 400 ms.
    • Use the SECTOR ERASE (SE) command to erase a specific sector.
  6. Read Operations:

    • The read time per byte is typically 25 ns, with a maximum of 50 ns.
    • Use the READ (READ) command to read data from the memory.
  7. Temperature Considerations:

    • The operating temperature range is from -40°C to 85°C.
    • The storage temperature range is from -65°C to 150°C.
  8. Data Retention:

    • The device guarantees data retention for at least 20 years under normal operating conditions.
  9. Package Information:

    • The M25P20-VMN6P is available in SOIC-8 and TSSOP-8 packages.
  10. Handling and Storage:

    • Handle the device with care to avoid static damage.
    • Store the device in a dry environment to prevent moisture damage.