Specifications
SKU: 11250097
Parameter | Symbol | Conditions | Min | Typ | Max | Unit |
---|---|---|---|---|---|---|
Supply Voltage | VCC | - | 2.0 | - | 6.0 | V |
Input Voltage Range | VI | - | -0.5 | - | VCC + 0.5 | V |
Output Voltage Range | VO | - | -0.5 | - | VCC + 0.5 | V |
Channel-to-Channel Leakage | ICL | VCC = 5V, TA = 25°C | - | ±0.01 | - | μA |
On-State Resistance | RON | VCC = 5V, IO = ±1mA, TA = 25°C | 35 | - | 85 | Ω |
Off-State Leakage Current | IOFF | VCC = 5V, VI = 0V, TA = 25°C | - | ±1 | - | nA |
Input Capacitance | CIN | f = 1 MHz, VCC = 5V | - | 10 | - | pF |
Output Capacitance | COUT | f = 1 MHz, VCC = 5V | - | 10 | - | pF |
Propagation Delay Time | tpd | VCC = 5V, TA = 25°C, VI = VOH or VOL | 10 | - | 30 | ns |
Power Dissipation | PD | Continuous, TA = 25°C | - | - | 100 | mW |
Instructions for Using the 74HC4051BQ:
Power Supply:
- Connect VCC to the positive supply voltage (2.0V to 6.0V).
- Connect GND to the ground.
Signal Inputs and Outputs:
- Connect the signal inputs (Y0 to Y7) to the channels you want to multiplex.
- Connect the common output (Z) to the point where you want to read the selected channel.
Control Signals:
- S0, S1, and S2 are the select lines that determine which channel is connected to the common output Z.
- INH is the inhibit input. When high, all channels are disconnected from the common output.
Channel Selection:
- Use the binary values on S0, S1, and S2 to select one of the eight channels (0 to 7).
- For example, to select channel 3, set S0 = 1, S1 = 1, and S2 = 0.
Inhibit Function:
- Set INH low to enable the multiplexer.
- Set INH high to disable the multiplexer and disconnect all channels from the common output.
Operating Temperature:
- The device is designed to operate over a temperature range of -40°C to +85°C.
Handling Precautions:
- Ensure that the input voltages do not exceed the supply voltage plus 0.5V or go below -0.5V to avoid damaging the device.
- Avoid exceeding the maximum power dissipation by ensuring proper heat sinking if necessary.
Storage and Handling:
- Store the device in a dry environment to prevent moisture damage.
- Handle with care to avoid static discharge, which can damage the internal circuits.