Share:


PCA9554DH

Specifications

SKU: 11250680

BUY PCA9554DH https://www.utsource.net/itm/p/11250680.html

Parameter Description Min Typ Max Unit
VCC Supply Voltage 1.7 - 5.5 V
ICC Supply Current (Active) - 200 - μA
IOL Output Low Current - 10 - mA
IOH Output High Current - -10 - mA
VIH Input High Voltage 0.7 × VCC - VCC V
VIL Input Low Voltage 0 - 0.3 × VCC V
fSCL Clock Frequency 0 - 400 kHz
tR Rise Time - 300 - ns
tF Fall Time - 300 - ns
TA Operating Temperature Range -40 - 85 °C
TSTG Storage Temperature Range -65 - 150 °C

Instructions for Using the PCA9554DH

  1. Power Supply:

    • Ensure the supply voltage (VCC) is within the range of 1.7V to 5.5V.
    • The typical supply current (ICC) is 200 μA.
  2. Input/Output Levels:

    • For input high (VIH), the voltage should be between 0.7 × VCC and VCC.
    • For input low (VIL), the voltage should be between 0 and 0.3 × VCC.
    • The output low current (IOL) can sink up to 10 mA.
    • The output high current (IOH) can source up to -10 mA.
  3. Communication:

    • The PCA9554DH supports I2C communication with a clock frequency (fSCL) up to 400 kHz.
    • Ensure the rise time (tR) and fall time (tF) of the I2C signals are within 300 ns.
  4. Temperature:

    • The operating temperature range (TA) is from -40°C to 85°C.
    • The storage temperature range (TSTG) is from -65°C to 150°C.
  5. Configuration:

    • Use the configuration registers to set the direction of the I/O pins (input or output).
    • Read and write data to the I/O ports using the appropriate I2C commands.
  6. Initialization:

    • Initialize the device by setting the configuration register according to your application requirements.
    • Ensure the device address is correctly configured if multiple devices are on the same I2C bus.
  7. Error Handling:

    • Monitor the I2C bus for any errors during communication.
    • Implement appropriate error handling mechanisms to ensure reliable operation.
  8. Power-On Reset:

    • The device has a power-on reset feature, ensuring all registers are initialized to default values upon power-up.

By following these instructions, you can effectively integrate the PCA9554DH into your project and ensure it operates reliably within the specified parameters.

(For reference only)

 Inquiry - PCA9554DH