Specifications
SKU: 11252763
Parameter | Symbol | Min | Typical | Max | Unit |
---|---|---|---|---|---|
Supply Voltage | VCC | 4.5 | - | 20 | V |
Output Current | IOUT | - | 1.0 | - | A |
Propagation Delay Time (High to Low) | tPLH | 150 | - | 300 | ns |
Propagation Delay Time (Low to High) | tPHL | 150 | - | 300 | ns |
Maximum Operating Temperature | TOP | -40 | - | 125 | °C |
Storage Temperature | TSTG | -65 | - | 150 | °C |
Isolation Voltage | VIORM | - | 2500 | - | Vrms |
Input Capacitance | CIN | - | 14 | - | pF |
Output Capacitance | COUT | - | 3 | - | pF |
Instructions for Using FOD3150:
Supply Voltage:
- Ensure the supply voltage (VCC) is within the range of 4.5V to 20V.
- Avoid exceeding the maximum supply voltage to prevent damage to the device.
Output Current:
- The device can provide up to 1.0A output current.
- Ensure the load does not exceed this limit to avoid overheating or failure.
Propagation Delay:
- The propagation delay times (tPLH and tPHL) are between 150ns and 300ns.
- These values are important for timing considerations in your circuit design.
Operating Temperature:
- The device is designed to operate within a temperature range of -40°C to 125°C.
- Ensure the ambient temperature stays within these limits to maintain reliable operation.
Storage Temperature:
- Store the device in an environment with temperatures ranging from -65°C to 150°C to prevent damage during storage.
Isolation Voltage:
- The device provides an isolation voltage of 2500Vrms, which is crucial for safety and performance in high-voltage applications.
Input and Output Capacitance:
- The input capacitance (CIN) is typically 14pF, and the output capacitance (COUT) is typically 3pF.
- These values should be considered when designing the input and output circuits to ensure proper signal integrity.
Mounting and Handling:
- Handle the device with care to avoid static discharge, which can damage the internal components.
- Follow recommended soldering and mounting procedures to ensure reliable connections and prevent thermal stress.
Testing and Verification:
- After assembly, test the device under typical operating conditions to verify its performance and functionality.
- Use appropriate test equipment to measure parameters such as output current, propagation delay, and isolation voltage.
By following these instructions, you can ensure the optimal performance and longevity of the FOD3150 in your application.
(For reference only)Inquiry - FOD3150