Specifications
SKU: 11254495
Parameter | Symbol | Conditions | Min | Typ | Max | Unit |
---|---|---|---|---|---|---|
Input Voltage | VI | Continuous operation | 20 | - | 35 | V |
Output Voltage | VO | No load to full load | - | 18 | - | V |
Output Current | IO | Continuous operation | - | 1.5 | - | A |
Line Regulation | ΔVO/ΔVI | 20V ≤ VI ≤ 35V | - | 0.04 | - | % |
Load Regulation | ΔVO/ΔIL | 0 ≤ IL ≤ 1.5A | - | 0.1 | - | % |
Dropout Voltage | VD | IO = 1.5A | - | 2.5 | - | V |
Quiescent Current | IQ | VI = 25V, no load | - | 5 | - | mA |
Thermal Resistance (θJA) | - | TO-220 package | - | 65 | - | °C/W |
Operating Temperature | TJ | Junction | -40 | - | 125 | °C |
Storage Temperature | TSTG | - | -65 | - | 150 | °C |
Instructions for Use:
Input Voltage:
- Ensure the input voltage is within the range of 20V to 35V to avoid damage or improper operation.
Output Voltage:
- The output voltage is regulated to 18V. Verify that this matches your application requirements.
Output Current:
- The device can provide up to 1.5A continuously. Ensure that the load does not exceed this limit to prevent overheating or failure.
Line Regulation:
- The output voltage changes by less than 0.04% for input voltage variations from 20V to 35V.
Load Regulation:
- The output voltage changes by less than 0.1% for load current variations from 0 to 1.5A.
Dropout Voltage:
- At full load (1.5A), the dropout voltage is 2.5V. Ensure that the input voltage is at least 20.5V to maintain regulation.
Quiescent Current:
- The quiescent current is typically 5mA at 25V input with no load. This should be considered in low-power applications.
Thermal Management:
- The thermal resistance (θJA) is 65°C/W for the TO-220 package. Use appropriate heatsinking if the device will operate near its maximum power dissipation.
Operating Temperature:
- The junction temperature should be kept between -40°C and 125°C to ensure reliable operation.
Storage Temperature:
- Store the device between -65°C and 150°C to prevent damage.
Mounting:
- Ensure proper mounting and soldering techniques to avoid mechanical stress and thermal issues.
Capacitors:
- Use input and output capacitors as recommended to stabilize the regulator and filter noise. Typically, a 0.33μF ceramic capacitor on the input and a 0.1μF ceramic capacitor on the output are sufficient.
PCB Layout:
- Keep the input and output leads short to minimize noise and improve stability.
Safety:
- Always follow safety guidelines when handling and testing high-voltage circuits.
Inquiry - LM7818CT