MAX233ACWP

Specifications

SKU: 11256408

BUY MAX233ACWP https://www.utsource.net/itm/p/11256408.html

Parameter Symbol Min Typ Max Unit Notes
Operating Voltage VCC 4.75 5.0 5.25 V
Input Voltage (TTL/CMOS) VIN 0 - 5.25 V
Output Voltage (RS-232) VOUT ±5 - ±15 V
Data Rate fD - 20 - kbps
Driver Output Current (Source/Sink) IOUT - 5 - mA
Receiver Input Current IIN - 1 - mA
Power Consumption (Active) PACT - 350 - μW
Power Consumption (Shutdown) PSTBY - 0.1 - μW
Operating Temperature TOPR -40 - 85 °C
Storage Temperature TSTG -65 - 150 °C

Instructions for Using MAX233ACWP:

  1. Power Supply:

    • Connect the VCC pin to a 5V power supply.
    • Ground the GND pin.
  2. TTL/CMOS Interface:

    • Connect the TTL/CMOS input signals to the RXD (Receiver Data) and CTS (Clear to Send) pins.
    • Connect the TTL/CMOS output signals from the TXD (Transmit Data) and RTS (Request to Send) pins.
  3. RS-232 Interface:

    • Connect the RS-232 output signals from the T1OUT and T2OUT pins to the corresponding RS-232 receiver inputs.
    • Connect the RS-232 input signals to the R1IN and R2IN pins from the corresponding RS-232 transmitter outputs.
  4. Capacitors:

    • Place 0.1μF capacitors close to the VCC and GND pins to filter out noise.
    • Use 10μF capacitors between the V+ and V- pins to provide charge storage for the internal charge pump.
  5. Data Rate:

    • Ensure that the data rate does not exceed 20 kbps to maintain reliable operation.
  6. Temperature Considerations:

    • Operate the device within the temperature range of -40°C to 85°C for optimal performance.
    • Store the device between -65°C and 150°C.
  7. Shutdown Mode:

    • To put the device into shutdown mode, connect the SHDN pin to VCC. This reduces power consumption to 0.1 μW.
  8. Layout Considerations:

    • Keep signal traces as short as possible to minimize noise and crosstalk.
    • Use ground planes to reduce noise and improve signal integrity.
  9. Handling Precautions:

    • Handle the device with care to avoid static damage.
    • Follow proper ESD (Electrostatic Discharge) precautions during handling and installation.
(For reference only)