Share:


K3569

Specifications

SKU: 11256657

BUY K3569 https://www.utsource.net/itm/p/11256657.html

Parameter Description Value
Part Number Component Identifier K3569
Type Type of Component Phototransistor
Package Enclosure or Package Type T1-3/4 (5mm)
Emission Color Color of Light Emitted Infrared (IR)
Peak Wavelength Wavelength of Peak Emission 940 nm
Forward Voltage Voltage at Which the Device Operates 1.2 V to 1.6 V
Forward Current Maximum Continuous Forward Current 50 mA
Reverse Voltage Maximum Reverse Voltage 5 V
Viewing Angle Angle of Maximum Light Intensity 10°
Operating Temperature Range of Temperatures for Operation -40°C to +85°C
Storage Temperature Range of Temperatures for Storage -40°C to +100°C
Rise Time Time to Reach 90% of Output 2 μs
Fall Time Time to Fall to 10% of Output 4 μs
Collector-Emitter Voltage Maximum Collector-Emitter Voltage 30 V
Collector Current Maximum Collector Current 50 mA
Collector-Emitter Saturation Voltage Voltage Drop at Saturation 0.5 V
Response Time Total Response Time (Rise + Fall) 6 μs

Instructions for Use:

  1. Handling:

    • Handle the K3569 with care to avoid damage to the leads and the body.
    • Use proper ESD (Electrostatic Discharge) precautions to prevent damage from static electricity.
  2. Mounting:

    • Ensure that the leads are bent carefully to avoid stress on the component.
    • Solder the leads quickly to avoid overheating the device. Use a temperature-controlled soldering iron and keep the soldering time to a minimum (less than 3 seconds).
  3. Circuit Design:

    • Connect the K3569 in series with a current-limiting resistor to ensure that the forward current does not exceed 50 mA.
    • Ensure that the reverse voltage across the phototransistor does not exceed 5 V to prevent damage.
    • Use a heat sink if the device will be operating at high currents or temperatures.
  4. Testing:

    • Test the K3569 using a known light source, such as an infrared LED, to verify its functionality.
    • Measure the collector-emitter voltage and current to ensure it is within the specified limits.
  5. Storage:

    • Store the K3569 in a dry, cool place away from direct sunlight and sources of heat.
    • Keep the components in their original packaging until ready for use to protect them from environmental factors.
  6. Disposal:

    • Dispose of the K3569 according to local regulations for electronic waste. Do not incinerate or dispose of in household trash.
(For reference only)