Specifications
SKU: 11262703
Parameter | Symbol | Min | Typical | Max | Unit | Notes |
---|---|---|---|---|---|---|
Forward Voltage | Vf | - | 1.8 | 2.2 | V | @ If = 20mA, Ta = 25°C |
Reverse Current | Ir | - | 100 | - | nA | @ Vr = 5V, Ta = 25°C |
Peak Forward Current | Ifsm | - | - | 100 | mA | Pulse Width ≤ 1ms, Duty Cycle ≤ 2% |
Operating Temperature | Topr | -40 | - | 85 | °C | |
Storage Temperature | Tstg | -65 | - | 150 | °C | |
Thermal Resistance | Rth | - | 200 | - | K/W | Junction to Ambient |
Wavelength | λD | 620 | 625 | 630 | nm | |
Viewing Angle | θv | - | 20 | - | ° |
Instructions:
Forward Current (If):
- Ensure that the forward current does not exceed 20mA for continuous operation.
- For pulse applications, do not exceed the peak forward current of 100mA with a pulse width ≤ 1ms and a duty cycle ≤ 2%.
Reverse Voltage (Vr):
- The reverse voltage should not exceed 5V to prevent damage.
Operating Temperature:
- The device is designed to operate within a temperature range of -40°C to 85°C.
Storage Temperature:
- Store the device in an environment where the temperature ranges from -65°C to 150°C.
Thermal Management:
- The thermal resistance from junction to ambient is 200 K/W. Ensure adequate heat dissipation to maintain the operating temperature within the specified range.
Wavelength and Viewing Angle:
- The emitted light has a wavelength between 620nm and 630nm, with a typical viewing angle of 20°.
Handling:
- Handle the device with care to avoid mechanical stress or damage.
- Use appropriate ESD protection measures to prevent electrostatic discharge damage.
Mounting:
- Follow the recommended soldering profile to ensure reliable mounting.
- Avoid excessive soldering temperatures and times to prevent damage to the device.
Inquiry - PDTC143ZT