Specifications
SKU: 11264923
Parameter | Symbol | Min | Typ | Max | Unit | Notes |
---|---|---|---|---|---|---|
Rated RMS On-State Current | IT(RMS) | - | 12 | - | A | |
Peak On-State Current (10 ms, non-repetitive) | ITSM | - | 144 | - | A | |
RMS Gate Trigger Current (Min) | IG(T)(RMS) | 15 | - | - | mA | |
Peak Gate Trigger Current (10 μs) | IGT(P) | 100 | - | - | mA | |
RMS Off-State Voltage | VDRM | - | 600 | - | V | |
Non-Repetitive Peak Off-State Voltage | VRRM | - | 800 | - | V | |
On-State Voltage at IT(RMS) = 12 A | VT | - | 1.2 | - | V | |
Holding Current | IH | - | 10 | - | mA | |
Power Dissipation (Tc = 25°C) | PD | - | 95 | - | W | |
Junction Temperature | TJ | - | - | 125 | °C | |
Storage Temperature | TSTG | -40 | - | 125 | °C |
Instructions for Using BTA12-600B TO220
Mounting and Handling:
- Ensure that the device is handled with care to avoid mechanical damage.
- Use a heatsink if the power dissipation exceeds the rated values for the ambient temperature.
- Apply thermal paste between the device and the heatsink for better heat transfer.
Electrical Connections:
- Connect the anode (A), cathode (K), and gate (G) terminals correctly.
- Ensure that the gate trigger current (IGT) is sufficient to turn on the triac reliably.
- Use appropriate wire gauges to handle the current ratings.
Operating Conditions:
- Do not exceed the maximum ratings for voltage, current, and temperature.
- Ensure that the junction temperature (TJ) does not exceed 125°C.
- Operate within the specified storage temperature range (-40°C to 125°C).
Testing and Troubleshooting:
- Test the device under controlled conditions to verify its operation.
- Check for proper triggering and on-state performance.
- Monitor the temperature and ensure adequate cooling.
Safety Precautions:
- Use appropriate safety equipment when handling high voltages and currents.
- Follow all relevant electrical safety guidelines and regulations.
- Ensure that the device is properly insulated to prevent short circuits and electric shock.
Storage:
- Store the device in a dry, cool place away from direct sunlight and extreme temperatures.
- Keep the device in its original packaging until ready for use to protect against static discharge.
Inquiry - BTA12-600B TO220