Share:


SGP40N60UF

Specifications

SKU: 11265638

BUY SGP40N60UF https://www.utsource.net/itm/p/11265638.html

Parameter Symbol Min Typ Max Unit
Breakdown Voltage V(BR)DSS - 600 - V
Continuous Drain Current (Tc = 25°C) ID - 40 - A
Pulse Drain Current (Tc = 25°C, t = 10 μs) Ipp - 200 - A
Gate-Source Voltage VGS -20 0 +20 V
Drain-Source On-State Resistance (VGS = 10 V, ID = 40 A) RDS(on) - 0.035 - Ω
Total Power Dissipation (Tc = 25°C) PD - 240 - W
Junction Temperature TJ -55 - +175 °C
Storage Temperature Range TSTG -55 - +175 °C
Thermal Resistance, Junction to Case RθJC - 0.5 - °C/W
Thermal Resistance, Junction to Ambient RθJA - 40 - °C/W

Instructions for Use:

  1. Handling Precautions:

    • Handle the SGP40N60UF with care to avoid damage to the device.
    • Use appropriate ESD protection to prevent static discharge.
  2. Mounting:

    • Ensure proper heat sinking to maintain the junction temperature within the specified range.
    • Follow the recommended PCB layout guidelines to minimize parasitic inductances and ensure reliable operation.
  3. Biasing:

    • Apply the gate-source voltage (VGS) within the specified limits to avoid damaging the device.
    • Ensure the drain-source voltage (VDS) does not exceed the breakdown voltage (V(BR)DSS).
  4. Current Handling:

    • Do not exceed the continuous drain current (ID) or pulse drain current (Ipp) ratings.
    • Monitor the device temperature to ensure it remains within the safe operating area (SOA).
  5. Thermal Management:

    • Use adequate cooling solutions to manage the power dissipation (PD) and keep the junction temperature (TJ) within the specified range.
    • Consider the thermal resistance (RθJC and RθJA) when designing the cooling system.
  6. Storage:

    • Store the device in a dry, cool environment within the storage temperature range (TSTG).
  7. Testing:

    • Perform initial testing under controlled conditions to verify the device parameters and performance.
    • Regularly inspect the device for signs of wear or damage during operation.
  8. Compliance:

    • Ensure that the device is used in compliance with all relevant safety and regulatory standards.
(For reference only)