Share:


W25Q40CLSNIG

Specifications

SKU: 11267327

BUY W25Q40CLSNIG https://www.utsource.net/itm/p/11267327.html

Parameter Symbol Min Typical Max Unit
Storage Temperature -40 85 °C
Operating Temperature -40 85 °C
Supply Voltage (Vcc) 2.7 3.6 V
Standby Current IDD 1 5 μA
Active Current IDD 5 20 mA
Programming Time TP 3 5 ms
Erase Time (Sector) TE 200 300 ms
Erase Time (Block) TE 1500 2000 ms
Write Protect Pin WP Active Low
Data Retention 20 Years
Endurance (Erase Cycles) 100,000 Cycles
Package Type SOP8
Memory Density 4 Mbit
Organization 512 K x 8

Instructions for Using W25Q40CLSNIG

  1. Power Supply:

    • Ensure the supply voltage (Vcc) is within the range of 2.7V to 3.6V.
    • Connect the ground (GND) pin to the system ground.
  2. Pin Configuration:

    • Vcc: Power supply.
    • GND: Ground.
    • HOLD#: Hold input, active low. Can be tied to Vcc if not used.
    • WP#: Write protect input, active low. Can be tied to Vcc if not used.
    • SI: Serial data input.
    • SO: Serial data output.
    • SCK: Serial clock input.
    • CS#: Chip select, active low.
  3. Initialization:

    • Set CS# low to select the device.
    • Apply the appropriate command sequence to initialize the device.
  4. Read Operations:

    • Use the Read Data command (03h) to read data from the memory.
    • Set up the address and read the data bytes.
  5. Write Operations:

    • Use the Write Enable command (06h) before any write operation.
    • Use the Page Program command (02h) to write data to the memory.
    • Ensure the write operation completes before issuing another command.
  6. Erase Operations:

    • Use the Sector Erase command (20h) to erase a sector.
    • Use the Block Erase command (52h or D8h) to erase a block.
    • Ensure the erase operation completes before writing new data.
  7. Status Register:

    • Use the Read Status Register command (05h) to check the status of the device.
    • The status register indicates whether the device is busy or ready for new commands.
  8. Write Protect:

    • Set WP# low to prevent write operations.
    • Setting WP# high allows write operations.
  9. Hold Function:

    • Set HOLD# low to pause ongoing operations.
    • Setting HOLD# high resumes operations.
  10. Data Retention and Endurance:

    • Ensure the device is operated within the specified temperature and voltage ranges to maintain data retention and endurance.
    • Avoid excessive erase cycles to prolong the life of the device.
  11. Handling and Storage:

    • Store the device in a dry, cool environment.
    • Handle with care to avoid static discharge and physical damage.

For detailed command sequences and timing diagrams, refer to the datasheet provided by the manufacturer.

(For reference only)

 Inquiry - W25Q40CLSNIG