Specifications
SKU: 11270543
Parameter | Symbol | Conditions | Min | Typ | Max | Unit |
---|---|---|---|---|---|---|
Forward Voltage | VF | IF = 20 mA | - | 1.2 | 1.5 | V |
Peak Reverse Voltage | VRRM | Non-repetitive | - | - | 600 | V |
Peak Repetitive Reverse Voltage | VRRM | Repetitive | - | - | 400 | V |
Forward Current | IF | Continuous | - | 20 | 30 | mA |
Peak Pulse Forward Current | IFPM | tp = 10 ms, Duty Cycle ≤ 1% | - | 100 | - | mA |
Zero Cross Detection Range | VZC | - | 0 | 1.5 | 3.5 | V |
Output Turn-On Time | ton | VDD = 220 VAC, RL = 100 Ω | - | 1.5 | 3.0 | ms |
Output Turn-Off Time | toff | VDD = 220 VAC, RL = 100 Ω | - | 1.5 | 3.0 | ms |
Isolation Voltage | VIORM | 1 minute, 50/60 Hz | - | - | 4000 | VRMS |
Operating Temperature | TA | Storage and Operation | -40 | - | 100 | °C |
Storage Temperature | TSTG | - | -40 | - | 100 | °C |
Instructions for Use:
Forward Voltage (VF):
- Ensure the forward voltage across the device does not exceed 1.5V when the forward current is 20mA.
Peak Reverse Voltage (VRRM):
- The device can withstand up to 600V in non-repetitive reverse conditions.
Peak Repetitive Reverse Voltage (VR RM):
- For repetitive reverse conditions, ensure the voltage does not exceed 400V.
Forward Current (IF):
- The continuous forward current should not exceed 30mA, with a typical value of 20mA.
Peak Pulse Forward Current (IFPM):
- The peak pulse forward current should not exceed 100mA for pulses of 10ms duration and a duty cycle of ≤1%.
Zero Cross Detection Range (VZC):
- The zero cross detection range is between 0 and 3.5V, with a typical value of 1.5V.
Output Turn-On and Turn-Off Time (ton, toff):
- The turn-on and turn-off times are typically 1.5ms and should not exceed 3.0ms under standard operating conditions.
Isolation Voltage (VIORM):
- The device provides isolation up to 4000VRMS for 1 minute at 50/60Hz.
Operating and Storage Temperature (TA, TSTG):
- The device can operate and be stored within a temperature range of -40°C to 100°C.
Handling and Storage:
- Static Sensitivity: Handle the device with care to avoid damage from static electricity.
- Moisture Sensitivity: Store the device in a dry environment to prevent moisture damage.
- Physical Handling: Avoid applying excessive force or bending to the leads.
Application Notes:
- Circuit Design: Ensure the circuit design accounts for the maximum ratings and typical parameters to ensure reliable operation.
- Thermal Management: Consider thermal management techniques if the device will be operating near its maximum current or temperature limits.
- Testing: Test the device under actual operating conditions to verify performance and reliability.