Specifications
SKU: 11281499
2SK3107 MOSFET N-Channel 30V 100mA/0.1A SOT-523/SC-75 marking D1 fast switch/low on-resistance/4V drive
Parameter | Symbol | Min | Typ | Max | Unit | Description |
---|---|---|---|---|---|---|
Drain-Source Voltage | V(DS) | - | - | 450 | V | Maximum drain-to-source voltage |
Gate-Source Voltage | V(GS) | -20 | - | 20 | V | Maximum gate-to-source voltage |
Drain Current | I(D) | - | - | 8 | A | Continuous drain current |
Gate Threshold Voltage | V(GS(th)) | 2 | 3.5 | 5 | V | Gate threshold voltage |
Transconductance | g(fs) | 3.5 | - | 9 | S | Transconductance at I(D) = 3A, V(DS) = 25V |
Input Capacitance | Ciss | - | 320 | - | pF | Input capacitance |
Output Capacitance | Coss | - | 45 | - | pF | Output capacitance |
Reverse Transfer Capacitance | Crss | - | 12 | - | pF | Reverse transfer capacitance |
Total Power Dissipation | P(TOT) | - | - | 150 | W | Total power dissipation |
Junction Temperature | Tj | -55 | - | 175 | °C | Operating junction temperature range |
Storage Temperature | Tstg | -55 | - | 150 | °C | Storage temperature range |
Instructions for Use:
Handling Precautions:
- Handle the 2SK3107 with care to avoid static damage.
- Use appropriate ESD protection when handling the device.
Mounting:
- Ensure proper heat sinking to manage the maximum power dissipation.
- Use thermal paste between the device and the heat sink for better thermal conductivity.
Biasing:
- Apply the gate-source voltage (V(GS)) carefully to stay within the specified limits.
- Ensure the gate threshold voltage (V(GS(th))) is met for proper operation.
Operation:
- Do not exceed the maximum drain-source voltage (V(DS)) or drain current (I(D)).
- Monitor the junction temperature (Tj) to prevent overheating.
Testing:
- Use a suitable test setup to measure parameters like transconductance (g(fs)), input capacitance (Ciss), output capacitance (Coss), and reverse transfer capacitance (Crss).
- Ensure all measurements are taken under controlled conditions to avoid damaging the device.
Storage:
- Store the 2SK3107 in a dry, cool place within the specified storage temperature range (Tstg).
Safety:
- Follow all safety guidelines and regulations when working with high voltages and currents.
- Use protective equipment as necessary.
Inquiry - 2SK3107