U1ZB24 Zener Diodes 24V 1W DO-214AC/SMA-24V marking 24 Constant-Voltage Regulation
Parameter Symbol Min Typical Max Unit Description
Input Voltage VIN 2.0 - 5.5 V Operating input voltage range
Output Voltage VOUT - 3.3 - V Fixed output voltage
Quiescent Current IQ - 0.1 - mA Current consumed by the regulator when no load is present
Output Current IOUT - 250 - mA Maximum continuous output current
Dropout Voltage VDROPOUT - 0.3 - V Voltage difference between VIN and VOUT at max IOUT
Shutdown Current ISD - 0.1 - μA Current consumed in shutdown mode
Thermal Shutdown TSD - 160 - °C Temperature at which the device shuts down to prevent damage
Operating Temp TOPR -40 - 85 °C Operating temperature range
Storage Temp TSTG -65 - 150 °C Storage temperature range

Instructions for Using U1ZB24

  1. Power Supply Connection:

    • Connect the input voltage (VIN) to the positive terminal of your power supply.
    • Ensure the input voltage is within the specified range (2.0V to 5.5V).
  2. Ground Connection:

    • Connect the ground (GND) pin to the common ground of your system.
  3. Output Connection:

    • Connect the output voltage (VOUT) pin to the load or circuit that requires a stable 3.3V supply.
  4. Capacitors:

    • Place a 1μF ceramic capacitor close to the input pin (VIN) to filter out noise and ensure stable operation.
    • Place a 1μF ceramic capacitor close to the output pin (VOUT) to stabilize the output voltage.
  5. Thermal Considerations:

    • Ensure adequate heat dissipation if operating at high output currents or in high ambient temperatures.
    • The device will automatically shut down if the junction temperature exceeds 160°C to prevent damage.
  6. Shutdown Mode:

    • To put the device into shutdown mode, pull the shutdown (SHDN) pin low. This reduces the current consumption to 0.1μA.
    • To resume normal operation, pull the SHDN pin high or leave it floating.
  7. PCB Layout:

    • Use a proper PCB layout with wide traces for power and ground to minimize voltage drops and improve thermal performance.
    • Keep the input and output capacitors as close as possible to the respective pins to minimize parasitic inductance and resistance.
  8. Testing:

    • Before connecting the load, test the output voltage with a multimeter to ensure it is stable and within the expected range.
    • Gradually increase the load current to verify the regulator can maintain the output voltage under different conditions.
  9. Storage and Handling:

    • Store the device in a dry environment within the specified storage temperature range (-65°C to 150°C).
    • Handle the device with care to avoid static discharge and physical damage.