Specifications
SKU: 11287895
Integrated Circuit(IC) Inverting Schmitt trigger TC7WH14FU SM8 marking H14
Parameter | Symbol | Min | Typical | Max | Unit | Conditions |
---|---|---|---|---|---|---|
Supply Voltage | VCC | 2.0 | - | 5.5 | V | Operating |
Input Voltage Range | VI | 0 | - | VCC | V | Operating |
Output Voltage Range | VO | 0 | - | VCC | V | Operating |
Output Current | IO | - | - | 50 | mA | Maximum |
Propagation Delay Time | tpd | - | 8 | - | ns | VCC = 5V, TA = 25°C |
Power Dissipation | PD | - | - | 150 | mW | Maximum, TA = 25°C |
Operating Temperature | TA | -40 | - | 85 | °C | Operating |
Storage Temperature | TSTG | -65 | - | 150 | °C | Storage |
Instructions for Use:
Power Supply:
- Ensure the supply voltage (VCC) is within the range of 2.0V to 5.5V.
- Connect the ground (GND) pin to a stable ground reference.
Input and Output Signals:
- The input voltage (VI) should be between 0V and VCC.
- The output voltage (VO) will also be between 0V and VCC.
Current Handling:
- The maximum output current (IO) is 50mA. Do not exceed this limit to avoid damaging the device.
Timing Considerations:
- The propagation delay time (tpd) is typically 8ns at VCC = 5V and TA = 25°C. Adjust your timing accordingly.
Thermal Management:
- The power dissipation (PD) should not exceed 150mW at room temperature (TA = 25°C).
- For extended operation at higher temperatures, ensure adequate heat sinking or cooling.
Temperature Ranges:
- The operating temperature range (TA) is from -40°C to 85°C.
- The storage temperature range (TSTG) is from -65°C to 150°C.
Handling Precautions:
- Handle the device with care to avoid static discharge, which can damage the internal circuits.
- Follow standard ESD (Electrostatic Discharge) precautions when handling the device.
Mounting and Soldering:
- Use appropriate soldering techniques to avoid overheating the device.
- Ensure all connections are secure and free from shorts or open circuits.