6R125P = IPW60R125CP

Specifications

SKU: 11301362

BUY 6R125P = IPW60R125CP https://www.utsource.net/itm/p/11301362.html

Parameter Symbol Value Unit
Maximum Drain-Source Voltage VDS(max) 600 V
Maximum Continuous Drain Current ID(max) 48 A
Peak Pulse Drain Current (t=10μs, Duty Cycle=1%) Ipp 300 A
Maximum Gate-Source Voltage VGS(max) ±20 V
On-State Resistance at 25°C, VGS=10V RDS(on) 0.125 Ω
On-State Resistance at 150°C, VGS=10V RDS(on) 0.187 Ω
Total Power Dissipation (Tc=25°C) PTOT 300 W
Junction Temperature Range TJ -55 to 175 °C
Storage Temperature Range TSTG -55 to 175 °C
Thermal Resistance, Junction to Case RθJC 0.6 °C/W
Thermal Resistance, Junction to Ambient RθJA 40 °C/W

Instructions for Use:

  1. Handling and Storage:

    • Store in a dry, cool place away from direct sunlight.
    • Handle with care to avoid mechanical damage or static discharge.
  2. Mounting:

    • Ensure proper heat sinking to manage thermal resistance.
    • Use appropriate mounting hardware to secure the device firmly.
  3. Electrical Connections:

    • Apply gate-source voltage (VGS) within the specified range to avoid damage.
    • Ensure drain-source voltage (VDS) does not exceed the maximum rating.
    • Keep continuous drain current (ID) within the rated limits.
  4. Thermal Management:

    • Monitor junction temperature (TJ) to ensure it stays within the operational range.
    • Use thermal paste between the device and heatsink for better thermal conductivity.
  5. Pulse Operation:

    • For pulse applications, ensure peak pulse drain current (Ipp) is within the specified limit and duty cycle is considered.
  6. Safety Precautions:

    • Do not exceed the maximum ratings under any operating conditions.
    • Use appropriate protective equipment when handling high voltages and currents.
  7. Testing:

    • Test the device under controlled conditions to verify performance before final integration into the circuit.
  8. Documentation:

    • Refer to the datasheet for detailed specifications and application notes.
    • Consult with the manufacturer for specific application advice if needed.