FCP11N60N

Specifications

SKU: 11303360

BUY FCP11N60N https://www.utsource.net/itm/p/11303360.html

Parameter Symbol Min Typ Max Unit Notes
Drain-Source Voltage VDS -60 - - V
Gate-Source Voltage VGS -20 - 20 V
Continuous Drain Current ID - 4.3 5.7 A @ VGS=10V, TC=25°C
Pulse Drain Current ID(p) - 18 - A @ VGS=10V, t=10μs, TC=25°C
Gate Charge QG - 45 - nC
Input Capacitance Ciss - 1100 - pF @ VDS=15V, f=1MHz
Output Capacitance Coss - 270 - pF @ VDS=15V, f=1MHz
Reverse Transfer Capacitance Crss - 180 - pF @ VDS=15V, f=1MHz
On-State Resistance RDS(on) - 1.5 2.2 Ω @ VGS=10V, ID=5A, TC=25°C
Threshold Voltage VGS(th) 2 3 4 V @ ID=250μA, TC=25°C
Power Dissipation PTOT - - 90 W @ TC=25°C
Junction Temperature TJ - - 150 °C
Storage Temperature TSTG -55 - 150 °C

Instructions for Use:

  1. Handling Precautions:

    • The FCP11N60N is sensitive to electrostatic discharge (ESD). Handle with care and use appropriate ESD protection measures.
    • Avoid exceeding the maximum ratings specified in the table to prevent damage to the device.
  2. Mounting and Soldering:

    • Ensure proper heat sinking to manage the power dissipation and maintain the junction temperature within safe limits.
    • Follow recommended soldering profiles to avoid thermal shock and ensure good electrical and mechanical connections.
  3. Operating Conditions:

    • Operate the device within the specified temperature range to ensure reliable performance.
    • Monitor the gate-source voltage to prevent it from exceeding the maximum rating, which can cause gate oxide breakdown.
  4. Gate Drive:

    • Use a low impedance gate drive circuit to minimize switching losses and ensure fast turn-on and turn-off times.
    • Ensure the gate resistor is appropriately chosen to control the switching speed and reduce electromagnetic interference (EMI).
  5. Thermal Management:

    • Use a heatsink or cooling solution to keep the junction temperature below the maximum limit, especially under high power conditions.
    • Consider the thermal resistance (RθJC) and the ambient temperature when designing the cooling system.
  6. Storage:

    • Store the device in a dry, cool place to prevent moisture absorption and degradation.
    • Keep the device in its original packaging until ready for use to protect against static and physical damage.
  7. Testing:

    • Use appropriate test equipment and procedures to verify the device parameters and ensure it meets the specified performance criteria.
    • Perform initial testing at room temperature and gradually increase the load to simulate actual operating conditions.