Specifications
SKU: 11303430
Parameter | Symbol | Value | Unit |
---|---|---|---|
Input Voltage | V_IN | 85 - 265 | VAC |
Output Voltage | V_OUT | 12 / 24 | VDC |
Output Current | I_OUT | 5 | A |
Efficiency | η | ≥ 87% | % |
Power Factor | PF | > 0.9 | - |
No-Load Power Consumption | P_NOLOAD | < 0.5 | W |
Operating Temperature | T_OP | -20 to +70 | °C |
Storage Temperature | T_ST | -40 to +85 | °C |
Humidity | RH | 0 to 95% (non-condensing) | % |
Protection Features | Overload, Short-Circuit, Over-Temperature | - | |
Certifications | CE, UL, CCC | - |
Instructions for Use:
Installation:
- Ensure the power supply is installed in a well-ventilated area to prevent overheating.
- Secure the power supply to a flat, stable surface using the provided mounting holes.
Connection:
- Connect the input terminals to the AC power source using the appropriate wiring.
- Connect the output terminals to the load device, ensuring correct polarity (positive to positive, negative to negative).
Operation:
- Turn on the power supply by connecting it to the AC mains.
- Monitor the output voltage and current to ensure they meet the specified values.
- If any protection features are triggered (overload, short-circuit, over-temperature), disconnect the power supply and check the connections and load.
Maintenance:
- Regularly inspect the power supply for any signs of damage or wear.
- Clean the power supply with a dry cloth to remove dust and debris.
- Do not expose the power supply to water or other liquids.
Troubleshooting:
- No Output Voltage: Check the input power connection and ensure the power supply is properly connected.
- Overheating: Ensure the power supply is adequately ventilated and not blocked by objects.
- Protection Features Activated: Disconnect the load and check for any faults in the load or wiring.
Disposal:
- Dispose of the power supply according to local regulations for electronic waste.
- Do not dispose of the power supply in household waste.
Inquiry - K31A60W