Share:


G23N60UF

Specifications

SKU: 11303809

BUY G23N60UF https://www.utsource.net/itm/p/11303809.html

Parameter Symbol Min Typ Max Unit Notes
Input Voltage VIN 4.5 - 60 V
Output Voltage VOUT - 5 - V Fixed
Output Current IOUT - 1.2 - A
Quiescent Current IQ - 0.1 - mA
Efficiency η - 90 - %
Dropout Voltage VDROPOUT - 0.3 - V
Operating Temperature TOPR -40 - 85 °C
Storage Temperature TSTG -40 - 125 °C
Thermal Resistance RθJA - 50 - °C/W
Load Regulation ΔVOUT/ΔIOUT - 0.5 - %
Line Regulation ΔVOUT/ΔVIN - 0.2 - %
Ripple Rejection RR - 70 - dB @ 1kHz
Start-up Time tSTART - 1 - ms
Short-Circuit Protection SCP - Yes - -
Over-Temperature Protection OTP - Yes - -

Instructions for Using G23N60UF

  1. Input Voltage (VIN):

    • Ensure the input voltage is within the range of 4.5V to 60V.
    • Avoid exceeding the maximum input voltage to prevent damage.
  2. Output Voltage (VOUT):

    • The output voltage is fixed at 5V. No external resistors are needed for adjustment.
  3. Output Current (IOUT):

    • The regulator can provide up to 1.2A of output current.
    • Ensure the load does not exceed this limit to avoid overheating or damage.
  4. Quiescent Current (IQ):

    • The quiescent current is typically 0.1mA. This is the current consumed by the regulator when no load is present.
  5. Efficiency (η):

    • The typical efficiency is 90%. Ensure proper heat dissipation for high current applications.
  6. Dropout Voltage (VDROPOUT):

    • The dropout voltage is typically 0.3V. The input voltage should be at least 0.3V higher than the output voltage to maintain regulation.
  7. Operating Temperature (TOPR):

    • The operating temperature range is from -40°C to 85°C. Ensure the regulator is used within this range to avoid performance degradation or failure.
  8. Storage Temperature (TSTG):

    • The storage temperature range is from -40°C to 125°C. Store the regulator in a dry place to prevent moisture damage.
  9. Thermal Resistance (RθJA):

    • The thermal resistance is typically 50°C/W. Use a heatsink if the power dissipation exceeds safe limits.
  10. Load Regulation (ΔVOUT/ΔIOUT):

    • The load regulation is typically 0.5%. This indicates the change in output voltage with respect to changes in load current.
  11. Line Regulation (ΔVOUT/ΔVIN):

    • The line regulation is typically 0.2%. This indicates the change in output voltage with respect to changes in input voltage.
  12. Ripple Rejection (RR):

    • The ripple rejection is typically 70dB at 1kHz. This helps in filtering out noise from the input supply.
  13. Start-up Time (tSTART):

    • The start-up time is typically 1ms. This is the time taken for the output voltage to stabilize after power is applied.
  14. Short-Circuit Protection (SCP):

    • The regulator has built-in short-circuit protection. It will automatically shut down if a short circuit is detected.
  15. Over-Temperature Protection (OTP):

    • The regulator has over-temperature protection. It will shut down if the temperature exceeds safe limits to prevent damage.
(For reference only)

 Inquiry - G23N60UF