Specifications
SKU: 11304654
Parameter | Symbol | Min | Typ | Max | Unit | Description |
---|---|---|---|---|---|---|
Drain-Source Voltage | VDS | - | - | 900 | V | Maximum voltage between drain and source with gate open |
Gate-Source Voltage | VGS | -30 | - | 30 | V | Maximum voltage between gate and source |
Continuous Drain Current | ID | - | 2.0 | - | A | Continuous current flowing from drain to source at TC = 25°C |
Pulse Drain Current | ID(p) | - | 11.0 | - | A | Peak pulse current flowing from drain to source (tp ≤ 10 μs, IAS = 0.6 × ID(p)) |
Power Dissipation | PTOT | - | - | 140 | W | Total power dissipation at TC = 25°C |
Junction Temperature | TJ | - | - | 175 | °C | Maximum allowable junction temperature |
Storage Temperature Range | TSTG | -65 | - | 150 | °C | Operating temperature range for storage and handling |
Instructions for Use:
Mounting and Handling:
- Ensure proper heat sinking to maintain the junction temperature within safe limits.
- Handle the device with care to avoid mechanical stress and static discharge.
Electrical Connections:
- Connect the drain (D), source (S), and gate (G) terminals correctly.
- Use appropriate wire gauges and connections to minimize resistance and inductance.
Biasing and Operation:
- Apply the gate-source voltage (VGS) within the specified range to control the device.
- Ensure the drain-source voltage (VDS) does not exceed the maximum rating to prevent breakdown.
Thermal Management:
- Monitor the junction temperature (TJ) to ensure it remains below the maximum limit.
- Use thermal paste and heatsinks to improve heat dissipation.
Pulse Operation:
- For pulse applications, ensure the pulse duration and frequency do not exceed the specified limits to avoid overheating.
Storage and Transportation:
- Store the device in a dry, cool environment within the specified storage temperature range.
- Use anti-static packaging during transportation to prevent damage from static electricity.
Safety Precautions:
- Always follow proper safety procedures when working with high voltages and currents.
- Use protective equipment such as gloves and goggles when handling the device.
For more detailed information, refer to the datasheet provided by STMicroelectronics.
(For reference only)Inquiry - STP2NK90Z