Specifications
SKU: 11526491
Parameter | Symbol | Min | Typical | Max | Unit |
---|---|---|---|---|---|
Input Voltage | VIN | 2.7 | - | 5.5 | V |
Output Voltage | VOUT | - | 3.3 | - | V |
Output Current | IOUT | - | 200 | 300 | mA |
Quiescent Current | IQ | - | 1.5 | - | μA |
Dropout Voltage | VDROPOUT | - | 200 | - | mV |
Operating Temp. | TOPR | -40 | - | 85 | °C |
Storage Temp. | TSTG | -65 | - | 150 | °C |
Instructions for Use:
Power Supply Connection:
- Connect the input voltage (VIN) to the positive terminal of the power supply.
- Ensure the input voltage is within the specified range of 2.7V to 5.5V.
Output Connection:
- Connect the output voltage (VOUT) to the load or circuit requiring regulated power.
- The output voltage is fixed at 3.3V.
Ground Connection:
- Connect the ground (GND) of the EN220A to the common ground of the power supply and the load.
Capacitors:
- Place a 1μF ceramic capacitor between VIN and GND as close as possible to the EN220A to ensure stability.
- Place a 1μF ceramic capacitor between VOUT and GND to filter the output and maintain stability.
Thermal Considerations:
- The EN220A can operate in temperatures ranging from -40°C to 85°C.
- For extended operation at high currents, ensure adequate heat dissipation to prevent overheating.
Storage:
- Store the EN220A in a dry environment with temperatures between -65°C and 150°C.
Handling:
- Handle the EN220A with care to avoid static damage. Use proper ESD protection measures.
Testing:
- Before connecting to the final application, test the EN220A with a known load to ensure it meets the required specifications.