Share:


ACS108-5SN

Specifications

SKU: 11530703

BUY ACS108-5SN https://www.utsource.net/itm/p/11530703.html

Parameter Symbol Min Typical Max Unit
Supply Voltage VCC 4.5 - 5.5 V
Output Current IO - 100 - mA
Sensitivity S 100 - 120 mV/A
Zero Current Output VOUT0 2.4 2.5 2.6 V
Bandwidth BW - 80 - kHz
Isolation Voltage VIORM - 2500 - Vrms
Operating Temperature TOPR -40 - 85 °C
Storage Temperature TSTG -40 - 125 °C
Response Time tR - 2 - μs
Overload Duration tOL - 100 - ms

Instructions for ACS108-5SN

  1. Supply Voltage (VCC):

    • Ensure the supply voltage is within the range of 4.5V to 5.5V. Operating outside this range can damage the device.
  2. Output Current (IO):

    • The output current should not exceed 100mA to avoid overheating and potential damage to the device.
  3. Sensitivity (S):

    • The sensitivity of the device is typically between 100mV/A and 120mV/A. This means that for every 1A of current sensed, the output voltage will change by 100mV to 120mV.
  4. Zero Current Output (VOUT0):

    • When no current is flowing through the sensor, the output voltage should be around 2.5V. This value can vary slightly between 2.4V and 2.6V.
  5. Bandwidth (BW):

    • The device has a bandwidth of 80kHz, meaning it can accurately measure current changes up to this frequency.
  6. Isolation Voltage (VIORM):

    • The device provides isolation up to 2500Vrms, which helps protect the circuit from high-voltage transients.
  7. Operating Temperature (TOPR):

    • The operating temperature range is from -40°C to 85°C. Ensure the device is used within this range to maintain optimal performance.
  8. Storage Temperature (TSTG):

    • Store the device in an environment with temperatures ranging from -40°C to 125°C to prevent damage.
  9. Response Time (tR):

    • The response time of the device is approximately 2μs, indicating how quickly it can react to changes in current.
  10. Overload Duration (tOL):

    • The device can handle overload conditions for up to 100ms without damage. However, prolonged exposure to overloads should be avoided.
  11. Installation:

    • Ensure proper installation and wiring to avoid short circuits or incorrect connections.
    • Use appropriate heat sinks if the device will be operated at high currents or temperatures.
  12. Testing:

    • Before deploying the device in a final application, perform thorough testing under various conditions to ensure reliable operation.
(For reference only)

 Inquiry - ACS108-5SN