Specifications
SKU: 11530703
Parameter | Symbol | Min | Typical | Max | Unit |
---|---|---|---|---|---|
Supply Voltage | VCC | 4.5 | - | 5.5 | V |
Output Current | IO | - | 100 | - | mA |
Sensitivity | S | 100 | - | 120 | mV/A |
Zero Current Output | VOUT0 | 2.4 | 2.5 | 2.6 | V |
Bandwidth | BW | - | 80 | - | kHz |
Isolation Voltage | VIORM | - | 2500 | - | Vrms |
Operating Temperature | TOPR | -40 | - | 85 | °C |
Storage Temperature | TSTG | -40 | - | 125 | °C |
Response Time | tR | - | 2 | - | μs |
Overload Duration | tOL | - | 100 | - | ms |
Instructions for ACS108-5SN
Supply Voltage (VCC):
- Ensure the supply voltage is within the range of 4.5V to 5.5V. Operating outside this range can damage the device.
Output Current (IO):
- The output current should not exceed 100mA to avoid overheating and potential damage to the device.
Sensitivity (S):
- The sensitivity of the device is typically between 100mV/A and 120mV/A. This means that for every 1A of current sensed, the output voltage will change by 100mV to 120mV.
Zero Current Output (VOUT0):
- When no current is flowing through the sensor, the output voltage should be around 2.5V. This value can vary slightly between 2.4V and 2.6V.
Bandwidth (BW):
- The device has a bandwidth of 80kHz, meaning it can accurately measure current changes up to this frequency.
Isolation Voltage (VIORM):
- The device provides isolation up to 2500Vrms, which helps protect the circuit from high-voltage transients.
Operating Temperature (TOPR):
- The operating temperature range is from -40°C to 85°C. Ensure the device is used within this range to maintain optimal performance.
Storage Temperature (TSTG):
- Store the device in an environment with temperatures ranging from -40°C to 125°C to prevent damage.
Response Time (tR):
- The response time of the device is approximately 2μs, indicating how quickly it can react to changes in current.
Overload Duration (tOL):
- The device can handle overload conditions for up to 100ms without damage. However, prolonged exposure to overloads should be avoided.
Installation:
- Ensure proper installation and wiring to avoid short circuits or incorrect connections.
- Use appropriate heat sinks if the device will be operated at high currents or temperatures.
Testing:
- Before deploying the device in a final application, perform thorough testing under various conditions to ensure reliable operation.