Specifications
SKU: 11531276
Parameter | Symbol | Min | Typical | Max | Unit | Conditions |
---|---|---|---|---|---|---|
Collector-Emitter Voltage | VCE(off) | - | 600 | - | V | IC = 0, Tj = 25°C to 150°C |
Gate-Emitter Voltage (Max) | VGE(max) | -20 | - | 20 | V | - |
Continuous Collector Current | IC | - | 50 | - | A | Tcase = 25°C |
Pulse Collector Current | IC(rms) | - | 100 | - | A | tp = 10 ms, Tcase = 25°C |
Total Power Dissipation | PT | - | 375 | - | W | Tcase = 25°C |
Junction Temperature | Tj | - | - | 150 | °C | - |
Storage Temperature Range | Tstg | -55 | - | 150 | °C | - |
Thermal Resistance (Junction to Case) | Rth(j-c) | - | 0.75 | - | °C/W | - |
Turn-On Time | ton | - | 0.28 | - | μs | IC = 50 A, VGE = 15 V, RG = 10 Ω |
Turn-Off Time | toff | - | 0.58 | - | μs | IC = 50 A, VGE = 15 V, RG = 10 Ω |
Saturation Voltage | VCE(sat) | - | 1.8 | - | V | IC = 50 A, VGE = 15 V, Tj = 25°C |
Gate Charge | QG | - | 120 | - | nC | IC = 50 A, VGE = 15 V, RG = 10 Ω |
Instructions for Use:
Mounting and Handling:
- Ensure proper heat sinking to maintain the junction temperature within the specified limits.
- Handle the device with care to avoid mechanical stress on the leads and the body.
Electrical Connections:
- Connect the collector (C), emitter (E), and gate (G) terminals correctly.
- Use appropriate gate resistors (RG) to control the switching speed and reduce EMI.
Thermal Management:
- Ensure adequate cooling to keep the case temperature below the maximum rating.
- Use thermal paste or a thermal pad between the device and the heat sink for better thermal conductivity.
Operating Conditions:
- Do not exceed the maximum ratings for voltage, current, and power dissipation.
- Operate within the specified temperature range to ensure reliable performance.
Storage:
- Store the device in a dry, cool place away from direct sunlight and corrosive environments.
- Avoid exposure to high humidity and extreme temperatures during storage.
Testing:
- Use a suitable test setup to verify the device parameters before integrating it into the final application.
- Follow the recommended test conditions to ensure accurate measurements.
Inquiry - 50G60HD FGW50N60HD TO-247 IGBT 600V 50A