Specifications
SKU: 11531284
Parameter | Symbol | Min | Typ | Max | Unit | Description |
---|---|---|---|---|---|---|
Forward Voltage Drop | V_F | - | 1.8 | 2.2 | V | At IF = 70A, T_J = 25°C |
Reverse Blocking Voltage | V_R | 1600 | - | - | V | Maximum reverse voltage |
Average Rectified Output Current | I_F(AV) | - | 70 | - | A | At T_A = 25°C, 50 Hz, single-phase full-wave rectifier circuit |
Peak Repetitive Reverse Voltage | V_RRM | - | 1600 | - | V | At I_RM = 0, T_J = 25°C |
Junction to Case Thermal Resistance | R_TH(JC) | - | 0.5 | - | °C/W | Thermal resistance from junction to case |
Storage Temperature Range | T_STG | -55 | - | 150 | °C | Operating temperature range |
Operating Temperature Range | T_J | -55 | - | 150 | °C | Junction temperature range |
Instructions for Use:
Mounting and Handling:
- Ensure proper heat sinking to maintain the junction temperature within the specified range.
- Use insulated tools to avoid short circuits during installation.
Electrical Connections:
- Connect the anode (A) and cathode (K) terminals correctly to avoid reverse polarity damage.
- Ensure all connections are secure to prevent thermal cycling and mechanical stress.
Thermal Management:
- Apply thermal paste between the device and the heatsink for optimal heat dissipation.
- Monitor the temperature of the heatsink to ensure it remains within safe operating limits.
Surge Currents:
- The device can handle surge currents, but ensure they do not exceed the maximum ratings to avoid damage.
- Use external fuses or current limiting resistors if necessary to protect against overcurrent conditions.
Storage and Handling:
- Store the device in a dry, cool place to prevent moisture damage.
- Handle with care to avoid physical damage to the leads and body.
Testing:
- Perform initial testing at low power levels to verify correct operation before applying full load.
- Use appropriate test equipment to measure parameters such as forward voltage drop and reverse blocking voltage.
Compliance:
- Ensure the device is used in compliance with relevant safety standards and regulations.
- Refer to the datasheet for detailed specifications and additional information.
Inquiry - 70TPS16 70A/1600V TO-247