Specifications
SKU: 11546398
Parameter | Symbol | Min | Typ | Max | Unit | Description |
---|---|---|---|---|---|---|
Input Voltage | VIN | - | 300 | 650 | V | Operating input voltage range |
Output Voltage | VOUT | - | 5 | 24 | V | Adjustable output voltage range |
Continuous Output Current | IOUT | - | 16 | 20 | A | Maximum continuous output current |
Peak Output Current | IPEAK | - | 24 | 28 | A | Maximum peak output current |
Switching Frequency | fSW | - | 100 | 500 | kHz | Switching frequency range |
Efficiency | η | 85 | 92 | 95 | % | Typical efficiency at full load |
Quiescent Current | IQ | - | 5 | 10 | mA | Quiescent current consumption |
Thermal Shutdown | TSD | - | 160 | 170 | °C | Temperature at which thermal shutdown occurs |
Operating Temperature | TOP | -40 | - | 125 | °C | Operating temperature range |
Storage Temperature | TSTG | -55 | - | 150 | °C | Storage temperature range |
Package Type | - | - | DIP | - | - | Dual In-line Package (DIP) |
Instructions for Use
Input Voltage:
- Ensure the input voltage is within the specified range of 300V to 650V. Exceeding this range can damage the device.
Output Voltage:
- Adjust the output voltage using the external resistors as per the datasheet recommendations. The output voltage can be set between 5V and 24V.
Output Current:
- The device can provide a continuous output current up to 20A, with a peak current of up to 28A. Ensure that the load does not exceed these limits to avoid overheating or damage.
Switching Frequency:
- The switching frequency can be set between 100kHz and 500kHz. Higher frequencies reduce the size of external components but may increase switching losses.
Efficiency:
- The efficiency of the device is typically between 85% and 95%. Optimize the design for maximum efficiency by minimizing losses in external components.
Thermal Management:
- The device has built-in thermal shutdown at temperatures between 160°C and 170°C. Ensure adequate cooling to keep the operating temperature below this threshold.
Operating and Storage Temperature:
- The device can operate in temperatures ranging from -40°C to 125°C and can be stored between -55°C and 150°C.
Package Handling:
- Handle the DIP package with care to avoid mechanical stress or damage to the leads. Follow standard ESD (Electrostatic Discharge) precautions during handling.
Mounting:
- Mount the device on a suitable heatsink if high power dissipation is expected. Ensure good thermal contact between the device and the heatsink.
Testing:
- Before deploying the device in a final application, test it under various conditions to ensure it meets the required performance specifications.
Inquiry - TYN616RG