Specifications
SKU: 11547500
Parameter | Symbol | Min | Typ | Max | Unit |
---|---|---|---|---|---|
Input Voltage | VIN | 70 | - | 400 | VAC |
Output Power | POUT | - | 3.5 | 12 | W |
Quiescent Current | IQ | - | 6 | - | mA |
Efficiency | η | - | 80 | - | % |
Operating Temperature | TOPR | -40 | - | 125 | °C |
Storage Temperature | TSTG | -65 | - | 150 | °C |
Isolation Voltage | VIORM | - | 2800 | - | VAC |
Load Regulation | RL | - | 5 | - | % |
Line Regulation | RL | - | 5 | - | % |
Output Ripple | Vripple | - | 100 | - | mVp-p |
Instructions for Using LNK302PN
Input Connection:
- Connect the input voltage (VIN) to the appropriate terminals on the LNK302PN. Ensure the input voltage is within the specified range (70-400 VAC).
Output Configuration:
- The output power (POUT) can be adjusted up to 12W. For optimal performance, keep the load regulation within 5% by using appropriate feedback circuits.
Heat Management:
- The operating temperature range is -40°C to 125°C. Ensure proper heat dissipation, especially when operating at higher temperatures or under heavy loads.
Isolation:
- The LNK302PN provides isolation up to 2800 VAC. Ensure that all connections are properly isolated to avoid electrical hazards.
Efficiency:
- The efficiency of the LNK302PN is typically around 80%. To maximize efficiency, use low-loss components and minimize parasitic losses in the circuit.
Quiescent Current:
- The quiescent current (IQ) is typically 6 mA. This should be considered in the overall power budget of your design.
Output Ripple:
- The output ripple voltage (Vripple) is typically 100 mV peak-to-peak. Use appropriate filtering techniques to reduce this if necessary.
Storage Conditions:
- Store the LNK302PN in a dry environment with temperatures ranging from -65°C to 150°C to ensure long-term reliability.
Testing and Validation:
- Before deploying the LNK302PN in a final product, thoroughly test the circuit under various conditions to ensure it meets all performance and safety requirements.
Compliance:
- Ensure that the design complies with relevant safety and regulatory standards, such as UL, CE, and IEC standards.