Specifications
SKU: 11548972
Parameter | Symbol | Min | Typical | Max | Unit |
---|---|---|---|---|---|
Reverse Breakdown Voltage | V(BR) | - | 36 | - | V |
Maximum Reverse Current | I(R) | - | 5 | - | μA |
Forward Voltage (I_F=1mA) | V(F) | 1.0 | 1.2 | 1.4 | V |
Operating Junction Temperature | T_J | -65 | - | 150 | °C |
Storage Temperature Range | T_STG | -65 | - | 150 | °C |
Power Dissipation | P_D | - | - | 200 | mW |
Instructions:
Handling and Storage:
- Store the device in a dry environment to prevent moisture damage.
- Handle with care to avoid mechanical stress or damage to the leads.
Mounting:
- Ensure proper alignment of the device during soldering to avoid short circuits.
- Use a temperature-controlled soldering iron to prevent thermal shock.
- Do not exceed the maximum power dissipation (200 mW) during operation.
Electrical Connections:
- Connect the device according to the polarity markings on the package.
- Ensure that the reverse breakdown voltage is not exceeded to prevent damage.
Operating Conditions:
- Operate the device within the specified operating junction temperature range (-65°C to 150°C).
- Monitor the forward current to ensure it does not exceed the rated values.
Testing:
- Use a multimeter or other appropriate test equipment to verify the forward and reverse characteristics.
- Test the device under controlled conditions to ensure accurate measurements.
Safety:
- Follow all safety guidelines when handling and testing the device.
- Use appropriate personal protective equipment (PPE) as necessary.
Inquiry - MMSZ5248B-7-F