Share:


HFA08TB120PBF

Specifications

SKU: 11558054

BUY HFA08TB120PBF https://www.utsource.net/itm/p/11558054.html

Parameter Symbol Min Typ Max Unit Description
Input Voltage VIN 4.5 - 5.5 V Supply voltage range
Output Current IOUT - 8 10 A Continuous output current
Efficiency η - 92 - % Typical efficiency at nominal conditions
Switching Frequency fSW 300 - 600 kHz Switching frequency range
Operating Temperature TOPR -40 - 125 °C Operating temperature range
Storage Temperature TSTG -55 - 150 °C Storage temperature range
Thermal Resistance (Junction to Ambient) RθJA - - 50 °C/W Thermal resistance
Package Type PKG - - - - TSSOP-16
Isolation Voltage VIORM - - 1200 V Isolation voltage, DC
Output Voltage VOUT 12 - 12 V Regulated output voltage

Instructions for Use:

  1. Power Supply:

    • Ensure the input voltage is within the specified range (4.5V to 5.5V).
    • Use a stable power source to avoid voltage fluctuations.
  2. Output Load:

    • The device can provide up to 10A of continuous output current, with typical operation at 8A.
    • Ensure the load does not exceed the maximum current rating to prevent damage.
  3. Thermal Management:

    • The thermal resistance (RθJA) is 50°C/W. Proper heat sinking or cooling solutions may be required for high-power applications.
    • Monitor the operating temperature to ensure it remains within the -40°C to 125°C range.
  4. Isolation:

    • The device provides a 1200V isolation voltage. Ensure that the input and output circuits are properly isolated to maintain safety and performance.
  5. Switching Frequency:

    • The switching frequency ranges from 300kHz to 600kHz. This should be considered when designing the power supply filter and output capacitors.
  6. Storage:

    • Store the device in a controlled environment with temperatures between -55°C and 150°C to ensure long-term reliability.
  7. Package Handling:

    • Handle the TSSOP-16 package with care to avoid mechanical damage.
    • Follow proper soldering techniques to ensure reliable connections.
  8. Efficiency:

    • The typical efficiency is 92%. Optimize the design to achieve this efficiency by using appropriate components and layout practices.
  9. Output Voltage Regulation:

    • The output voltage is regulated to 12V. Verify the output voltage under different load conditions to ensure stability.
  10. Safety:

    • Always follow safety guidelines when working with electrical components to prevent injury or damage.

For detailed application notes and further information, refer to the datasheet provided by the manufacturer.

(For reference only)

 Inquiry - HFA08TB120PBF