Parameter | Symbol | Min | Typ | Max | Unit | Description |
---|---|---|---|---|---|---|
Supply Voltage | Vcc | 4.5 | 5.0 | 5.5 | V | Operating supply voltage range |
Supply Current | Icc | - | 10 | 30 | mA | Supply current at Vcc = 5V, no load |
Output Voltage | Vo | 0 | - | 5.0 | V | Output voltage range (open collector) |
Output Current | Io | - | 20 | 50 | mA | Maximum output current per channel |
Channel Isolation | - | - | - | 50 | kΩ | Isolation resistance between channels |
Operating Temperature | Toper | -40 | - | 85 | °C | Operating temperature range |
Storage Temperature | Tstg | -65 | - | 150 | °C | Storage temperature range |
Rise Time | tr | - | 10 | 20 | μs | Rise time (20% to 80%) |
Fall Time | tf | - | 10 | 20 | μs | Fall time (80% to 20%) |
Input Voltage | Vi | 0 | - | 5.0 | V | Input voltage range |
Input Current | Ii | - | 0.1 | 1.0 | mA | Input current at Vcc = 5V |
Power Dissipation | Pd | - | - | 1000 | mW | Maximum power dissipation (derated above 25°C) |
Instructions for Use:
Supply Voltage (Vcc):
- Ensure the supply voltage is within the specified range of 4.5V to 5.5V.
- Connect the Vcc pin to the positive terminal of the power supply.
Ground Connection:
- Connect the GND pin to the common ground of the system.
Input Signal:
- Apply the input signal to the input pins (IN1, IN2, etc.). The input voltage should be within the range of 0V to 5V.
- The input current should not exceed 1mA.
Output Configuration:
- The output pins (OUT1, OUT2, etc.) are open collector and can sink up to 50mA of current.
- Connect a pull-up resistor from the output pin to the desired supply voltage (typically 5V) to set the high state level.
Channel Isolation:
- Channels are electrically isolated from each other with a minimum isolation resistance of 50kΩ.
Temperature Considerations:
- Ensure the operating temperature is within -40°C to 85°C.
- For storage, keep the device within -65°C to 150°C.
Power Dissipation:
- The maximum power dissipation is 1000mW. Derate the power dissipation above 25°C to avoid overheating.
Timing Parameters:
- The rise and fall times are typically 10μs but can vary between 10μs and 20μs.
Handling Precautions:
- Handle the device with care to avoid static damage.
- Follow proper soldering techniques to ensure reliable connections.
Mounting:
- Mount the device on a PCB with adequate heat sinking if high power dissipation is expected.
- Ensure proper mechanical support to prevent physical stress on the device.
By following these parameters and instructions, you can ensure optimal performance and reliability of the UPB8284AD.
(For reference only)Inquiry - UPB8284AD