Specifications
SKU: 11582305
Parameter | Symbol | Min | Typ | Max | Unit |
---|---|---|---|---|---|
Input Voltage | V_IN | 4.5 | - | 20 | V |
Output Voltage | V_OUT | 0.8 | - | 5.5 | V |
Output Current | I_OUT | - | 2.0 | 3.0 | A |
Quiescent Current | I_Q | - | 60 | 120 | μA |
Efficiency | η | - | 92 | - | % |
Switching Frequency | f_SW | 300 | 500 | 700 | kHz |
Dropout Voltage | V_DO | - | 200 | 400 | mV |
Load Regulation | ΔV_OUT | - | 1.0 | 2.0 | % |
Line Regulation | ΔV_OUT | - | 0.5 | 1.0 | % |
Thermal Shutdown | T_SD | - | 160 | - | °C |
Operating Temperature | T_OP | -40 | - | 125 | °C |
Storage Temperature | T_STG | -65 | - | 150 | °C |
Instructions for Use
Input Voltage (V_IN):
- Ensure the input voltage is within the range of 4.5V to 20V.
- Avoid exceeding the maximum input voltage to prevent damage.
Output Voltage (V_OUT):
- Set the output voltage between 0.8V and 5.5V using the external feedback resistors.
- Verify the output voltage with a multimeter before connecting the load.
Output Current (I_OUT):
- The device can provide a continuous output current up to 3.0A.
- For optimal performance, operate within the typical range of 2.0A.
Quiescent Current (I_Q):
- The quiescent current is typically around 60μA and can increase to 120μA under certain conditions.
- This current is drawn even when there is no load on the output.
Efficiency (η):
- The efficiency is typically around 92%.
- Monitor the efficiency to ensure optimal performance and heat dissipation.
Switching Frequency (f_SW):
- The switching frequency can be set between 300kHz and 700kHz.
- Adjust the frequency based on the application requirements and component values.
Dropout Voltage (V_DO):
- The dropout voltage is typically around 200mV and can increase to 400mV.
- Ensure the input voltage is sufficiently higher than the output voltage to maintain regulation.
Load Regulation (ΔV_OUT):
- The load regulation is typically around 1.0% and can vary up to 2.0%.
- This indicates how much the output voltage changes with varying load currents.
Line Regulation (ΔV_OUT):
- The line regulation is typically around 0.5% and can vary up to 1.0%.
- This indicates how much the output voltage changes with varying input voltages.
Thermal Shutdown (T_SD):
- The device will automatically shut down if the temperature exceeds 160°C.
- Ensure proper heat sinking and ventilation to prevent thermal shutdown.
Operating Temperature (T_OP):
- The operating temperature range is from -40°C to 125°C.
- Ensure the device operates within this range to avoid performance degradation or failure.
Storage Temperature (T_STG):
- The storage temperature range is from -65°C to 150°C.
- Store the device in a dry, cool place to ensure long-term reliability.
Inquiry - SI3122P,3122P