AD592ANZ

Specifications

SKU: 11583841

BUY AD592ANZ https://www.utsource.net/itm/p/11583841.html

Parameter Symbol Conditions Min Typ Max Unit
Supply Voltage Vcc 4.0 5.0 30.0 V
Operating Temperature Range Toper -55 150 °C
Storage Temperature Range Tstg -65 175 °C
Output Current at 0°C Iout(0) Vcc = 5V 298 300 302 μA
Output Current at 25°C Iout(25) Vcc = 5V 473 475 477 μA
Output Current at 100°C Iout(100) Vcc = 5V 1298 1300 1302 μA
Nonlinearity 0°C to 100°C ±0.15 %FS
Thermal Sensitivity S 0°C to 100°C 10.0 10.0 10.0 μA/°C
Zero Current Error Ierr(0) 0°C -2 0 +2 μA
Span Error Ispan 0°C to 100°C -1 0 +1 %FS
Long-Term Stability 1 year at 25°C ±0.1 %FS/yr
Response Time τ Step change from 0°C to 100°C 5 ms

Instructions for Use:

  1. Supply Voltage:

    • Ensure the supply voltage is within the range of 4.0V to 30.0V.
    • A stable power supply is recommended to avoid fluctuations that could affect performance.
  2. Temperature Range:

    • The AD592ANZ operates effectively between -55°C and 150°C.
    • Store the device between -65°C and 175°C to ensure long-term reliability.
  3. Output Current:

    • At 0°C, the output current should be around 300μA.
    • At 25°C, the output current should be around 475μA.
    • At 100°C, the output current should be around 1300μA.
    • Use these values to calibrate your system for accurate temperature measurements.
  4. Nonlinearity:

    • The nonlinearity over the range from 0°C to 100°C is ±0.15% of full scale (FS).
  5. Thermal Sensitivity:

    • The thermal sensitivity is 10.0 μA/°C, which means the output current increases by 10.0 μA for each degree Celsius increase in temperature.
  6. Zero Current Error:

    • The zero current error at 0°C is ±2 μA. This should be accounted for in your calibration process.
  7. Span Error:

    • The span error over the range from 0°C to 100°C is ±1% FS. Adjust your system to correct for this error.
  8. Long-Term Stability:

    • The long-term stability is ±0.1% FS per year at 25°C. Regular recalibration may be necessary to maintain accuracy.
  9. Response Time:

    • The response time for a step change from 0°C to 100°C is 5 ms. This is important for applications requiring fast temperature measurements.
  10. Handling:

    • Handle the device with care to avoid mechanical stress or damage.
    • Follow standard ESD (Electrostatic Discharge) precautions to prevent damage to the component.

By following these parameters and instructions, you can ensure optimal performance and reliability of the AD592ANZ temperature sensor.

(For reference only)