Share:


TLP291-4GB

Specifications

SKU: 11592672

BUY TLP291-4GB https://www.utsource.net/itm/p/11592672.html

Parameter Symbol Min Typ Max Unit Conditions
Supply Voltage VCC 3.0 - 5.5 V -
Output Current (Sink) IO(sink) - 15 - mA VCE = 5V, Ta = 25°C
Output Current (Source) IO(source) - 10 - mA VCE = 5V, Ta = 25°C
Input Current IF 5 10 20 mA VCC = 5V, Ta = 25°C
Forward Voltage VF 1.2 1.5 1.8 V IF = 10mA
Isolation Voltage VIORM - - 5000 VRMS -
Operating Temperature TA -40 - 105 °C -
Storage Temperature TSTG -55 - 125 °C -
Maximum Junction Temperature TJ(max) - - 125 °C -
Leakage Current IOL - 0.1 - μA VCC = 5V, Ta = 25°C
Propagation Delay Time tPLH, tPHL - 2.5 4.5 μs VCC = 5V, IF = 10mA, RL = 500Ω, Ta = 25°C
Rise Time tr - 1.0 2.0 μs VCC = 5V, IF = 10mA, RL = 500Ω, Ta = 25°C
Fall Time tf - 1.0 2.0 μs VCC = 5V, IF = 10mA, RL = 500Ω, Ta = 25°C

Instructions for Use:

  1. Power Supply:

    • Ensure the supply voltage (VCC) is within the range of 3.0V to 5.5V.
    • Connect the VCC pin to the positive supply and GND to the ground.
  2. Input Connection:

    • Connect the input signal to the Anode (A) and Cathode (K) pins.
    • The input current (IF) should be between 5mA and 20mA for reliable operation.
  3. Output Connection:

    • Connect the load between the Output (O) pin and ground.
    • The output can sink up to 15mA and source up to 10mA.
  4. Temperature Considerations:

    • Operate the device within the temperature range of -40°C to 105°C.
    • Store the device within the temperature range of -55°C to 125°C.
  5. Isolation:

    • The device provides an isolation voltage of up to 5000VRMS between the input and output sides.
  6. Timing Parameters:

    • Ensure that the propagation delay time (tPLH, tPHL) is within the specified range for proper signal transmission.
    • The rise time (tr) and fall time (tf) should also be considered for high-speed applications.
  7. Leakage Current:

    • The leakage current (IOL) should be kept below 0.1μA to avoid unwanted triggering.
  8. Mounting and Handling:

    • Handle the device with care to avoid mechanical stress.
    • Follow standard ESD (Electrostatic Discharge) precautions during handling and assembly.

By following these parameters and instructions, you can ensure optimal performance and reliability of the TLP291-4GB optocoupler.

(For reference only)