Specifications
SKU: 11622713
Parameter | Symbol | Conditions | Min | Typ | Max | Unit |
---|---|---|---|---|---|---|
Input Voltage | VIN | Continuous Operation | 2.7 | - | 5.5 | V |
Output Current | IOUT | Continuous Operation | - | 1.5 | 3.0 | A |
Quiescent Current | IQ | VIN = 5V, No Load | - | 1.5 | - | mA |
Dropout Voltage | VDROP | IOUT = 3A, VIN = 5V | - | 0.4 | - | V |
Thermal Shutdown | TSHUTDOWN | - | - | 160 | - | °C |
Operating Temperature | TOP | - | -40 | - | 125 | °C |
Storage Temperature | TSTORAGE | - | -65 | - | 150 | °C |
Instructions for Use:
Power Supply:
- Ensure the input voltage (VIN) is within the specified range of 2.7V to 5.5V.
- The device can handle continuous output currents up to 3A.
Thermal Management:
- Monitor the operating temperature to ensure it does not exceed 125°C.
- If the device reaches the thermal shutdown threshold of 160°C, it will automatically turn off to prevent damage.
Quiescent Current:
- The quiescent current (IQ) is typically 1.5mA at 5V input with no load.
Dropout Voltage:
- The dropout voltage (VDROP) is typically 0.4V when the output current is 3A and the input voltage is 5V.
Storage:
- Store the device in an environment where the temperature does not fall below -65°C or rise above 150°C.
Mounting and Handling:
- Follow standard ESD (Electrostatic Discharge) precautions during handling and installation.
- Ensure proper mounting to maintain thermal performance and reliability.
Application Notes:
- For optimal performance, use appropriate decoupling capacitors on both the input and output sides.
- Refer to the datasheet for detailed application circuits and recommendations.