Parameter | Symbol | Min | Typical | Max | Unit | Notes |
---|---|---|---|---|---|---|
Supply Voltage | VCC | 4.5 | - | 5.5 | V | Operating voltage range |
Standby Current | ICCS | - | 20 | 40 | μA | Quiescent current in standby mode |
Active Current | ICCA | - | 30 | 50 | mA | Current consumption during active operation |
Access Time | tAA | - | 70 | 90 | ns | Time from valid address to data output |
Cycle Time | tCYC | - | 150 | 200 | ns | Minimum time between consecutive accesses |
Data Hold Time | tDH | 0 | - | 5 | ns | Minimum time data must be held after clock edge |
Address Setup Time | tAS | 10 | - | 15 | ns | Minimum time address must be stable before clock edge |
Output Enable Time | tOE | 0 | - | 5 | ns | Time from OE low to valid data output |
Write Enable Time | tWE | 0 | - | 5 | ns | Time from WE low to start of write cycle |
Write Recovery Time | tWR | 10 | - | 15 | ns | Time from WE high to next valid operation |
Power-down Time | tPD | 0 | - | 5 | ns | Time from CE high to power-down state |
Power-up Time | tPU | 0 | - | 5 | μs | Time from VCC applied to valid operation |
Data Retention Time | tRET | - | - | 20 | years | Data retention at specified temperature range |
Operating Temperature | Toper | -40 | - | 85 | °C | Range for normal operation |
Storage Temperature | Tstg | -65 | - | 150 | °C | Range for storage without damage |
Instructions for Using M5K4164ANP-15
Power Supply:
- Ensure the supply voltage (VCC) is within the range of 4.5V to 5.5V.
- Connect the ground (GND) pin to a stable ground reference.
Addressing:
- Apply the address signals (A0-A12) to select the desired memory location.
- Ensure the address setup time (tAS) is met before the clock edge.
Data I/O:
- Data input/output (DQ0-DQ7) should be connected to the system bus.
- Ensure the data hold time (tDH) is met after the clock edge.
Control Signals:
- Chip Enable (CE): Low to enable the device, high to put it in standby.
- Output Enable (OE): Low to enable data output, high to disable.
- Write Enable (WE): Low to initiate a write cycle, high to complete the write cycle.
Timing:
- Follow the specified access time (tAA) and cycle time (tCYC) to ensure proper operation.
- Observe the write recovery time (tWR) to prevent data corruption.
Power Management:
- Use the power-down feature by setting CE high to reduce power consumption.
- Allow sufficient power-up time (tPU) when re-enabling the device.
Environmental Conditions:
- Operate the device within the specified operating temperature range (-40°C to 85°C).
- Store the device within the storage temperature range (-65°C to 150°C).
Handling:
- Handle the device with care to avoid static discharge, which can damage the internal circuits.
- Use appropriate ESD protection measures during handling and installation.
By following these parameters and instructions, you can ensure reliable and efficient operation of the M5K4164ANP-15 memory device.
(For reference only)Inquiry - M5K4164ANP-15