Share:


M5K4164ANP-15

Specifications

SKU: 11624301

BUY M5K4164ANP-15 https://www.utsource.net/itm/p/11624301.html

Parameter Symbol Min Typical Max Unit Notes
Supply Voltage VCC 4.5 - 5.5 V Operating voltage range
Standby Current ICCS - 20 40 μA Quiescent current in standby mode
Active Current ICCA - 30 50 mA Current consumption during active operation
Access Time tAA - 70 90 ns Time from valid address to data output
Cycle Time tCYC - 150 200 ns Minimum time between consecutive accesses
Data Hold Time tDH 0 - 5 ns Minimum time data must be held after clock edge
Address Setup Time tAS 10 - 15 ns Minimum time address must be stable before clock edge
Output Enable Time tOE 0 - 5 ns Time from OE low to valid data output
Write Enable Time tWE 0 - 5 ns Time from WE low to start of write cycle
Write Recovery Time tWR 10 - 15 ns Time from WE high to next valid operation
Power-down Time tPD 0 - 5 ns Time from CE high to power-down state
Power-up Time tPU 0 - 5 μs Time from VCC applied to valid operation
Data Retention Time tRET - - 20 years Data retention at specified temperature range
Operating Temperature Toper -40 - 85 °C Range for normal operation
Storage Temperature Tstg -65 - 150 °C Range for storage without damage

Instructions for Using M5K4164ANP-15

  1. Power Supply:

    • Ensure the supply voltage (VCC) is within the range of 4.5V to 5.5V.
    • Connect the ground (GND) pin to a stable ground reference.
  2. Addressing:

    • Apply the address signals (A0-A12) to select the desired memory location.
    • Ensure the address setup time (tAS) is met before the clock edge.
  3. Data I/O:

    • Data input/output (DQ0-DQ7) should be connected to the system bus.
    • Ensure the data hold time (tDH) is met after the clock edge.
  4. Control Signals:

    • Chip Enable (CE): Low to enable the device, high to put it in standby.
    • Output Enable (OE): Low to enable data output, high to disable.
    • Write Enable (WE): Low to initiate a write cycle, high to complete the write cycle.
  5. Timing:

    • Follow the specified access time (tAA) and cycle time (tCYC) to ensure proper operation.
    • Observe the write recovery time (tWR) to prevent data corruption.
  6. Power Management:

    • Use the power-down feature by setting CE high to reduce power consumption.
    • Allow sufficient power-up time (tPU) when re-enabling the device.
  7. Environmental Conditions:

    • Operate the device within the specified operating temperature range (-40°C to 85°C).
    • Store the device within the storage temperature range (-65°C to 150°C).
  8. Handling:

    • Handle the device with care to avoid static discharge, which can damage the internal circuits.
    • Use appropriate ESD protection measures during handling and installation.

By following these parameters and instructions, you can ensure reliable and efficient operation of the M5K4164ANP-15 memory device.

(For reference only)

 Inquiry - M5K4164ANP-15