Share:


PS9121

Specifications

SKU: 11626877

BUY PS9121 https://www.utsource.net/itm/p/11626877.html

Parameter Symbol Min Typ Max Unit Description
Supply Voltage VDD 2.7 - 5.5 V Operating supply voltage range
Output Current IOUT - 100 300 mA Continuous output current
Quiescent Current IQ - 1.6 - μA Quiescent current at no load
Dropout Voltage VDROPOUT - 0.4 0.8 V Dropout voltage at IOUT = 300 mA
Load Regulation - - 0.2 0.5 % Load regulation from 0 to 300 mA
Line Regulation - - 0.02 0.05 %/V Line regulation over full VDD range
Thermal Shutdown TSD - 160 - °C Thermal shutdown temperature
Short-Circuit Current ISC - 350 500 mA Short-circuit current limit
Operating Temperature TOPR -40 - 125 °C Operating temperature range
Storage Temperature TSTG -65 - 150 °C Storage temperature range

Instructions for Using the PS9121

  1. Supply Voltage (VDD):

    • Ensure the supply voltage is within the range of 2.7V to 5.5V. Exceeding this range can damage the device.
  2. Output Current (IOUT):

    • The PS9121 can provide up to 300 mA continuously. Avoid exceeding this limit to prevent overheating and potential damage.
  3. Quiescent Current (IQ):

    • The quiescent current is typically 1.6 μA when there is no load. This low current consumption makes the PS9121 suitable for battery-powered applications.
  4. Dropout Voltage (VDROPOUT):

    • The dropout voltage is typically 0.4V and can go up to 0.8V at the maximum output current. Ensure that the input voltage is at least this much higher than the desired output voltage.
  5. Load Regulation:

    • The load regulation is typically 0.2% and can vary up to 0.5%. This indicates how well the output voltage remains stable under varying load conditions.
  6. Line Regulation:

    • The line regulation is typically 0.02% per volt and can vary up to 0.05% per volt. This indicates how well the output voltage remains stable with changes in input voltage.
  7. Thermal Shutdown (TSD):

    • The device will shut down if the internal temperature reaches approximately 160°C to prevent damage. Allow the device to cool before resuming operation.
  8. Short-Circuit Current (ISC):

    • The short-circuit current limit is typically 350 mA and can go up to 500 mA. The device will automatically limit the current to protect itself from damage.
  9. Operating Temperature (TOPR):

    • The operating temperature range is from -40°C to 125°C. Ensure that the device operates within this range to avoid performance issues or damage.
  10. Storage Temperature (TSTG):

    • The storage temperature range is from -65°C to 150°C. Store the device in a dry, cool place to ensure its longevity.

Additional Notes:

  • Capacitors:
    • Use appropriate input and output capacitors to stabilize the supply and output voltages. Typical values are 1 μF for both input and output.
  • PCB Layout:
    • Ensure proper PCB layout to minimize noise and improve thermal performance. Keep the input and output traces short and wide.
  • Heat Sinking:
    • For high current applications, consider adding a heat sink to the device to dissipate heat more effectively.
(For reference only)

 Inquiry - PS9121