Parameter Symbol Test Conditions Min Typical Max Unit
Drain-to-Source Voltage VDS 300 V
Gate-to-Source Voltage VGS -15 +20 V
Continuous Drain Current ID TC = 25°C 70 A
Pulse Drain Current ID(pulse) tp = 10 μs, IG = 10 A 140 A
Gate Charge QG VDS = 25 V, ID = 25 A 100 120 140 nC
Input Capacitance Ciss f = 1 MHz 1900 2200 2500 pF
Output Capacitance Coss f = 1 MHz 200 250 300 pF
Reverse Transfer Capacitance Crss VDS = 25 V, ID = 25 A 40 50 60 pF
Threshold Gate Voltage VGS(th) ID = 250 μA 2.0 3.0 4.0 V
On-State Resistance RDS(on) VGS = 10 V, ID = 25 A 1.5 2.0 2.5
Total Power Dissipation PTOT TC = 25°C 240 W
Junction Temperature TJ -55 175 °C
Storage Temperature Tstg -55 150 °C

Instructions for Use:

  1. Mounting and Handling:

    • Ensure that the device is mounted on a suitable heatsink to manage the heat dissipation effectively.
    • Handle the device with care to avoid damage to the leads and the die.
  2. Electrical Connections:

    • Connect the drain (D) to the high-voltage side of the circuit.
    • Connect the source (S) to the low-voltage side or ground.
    • Connect the gate (G) to the control circuit ensuring proper isolation to prevent short circuits.
  3. Gate Drive:

    • Use a gate driver with appropriate voltage levels to ensure reliable switching.
    • Ensure the gate-to-source voltage (VGS) does not exceed the maximum ratings to avoid damage.
  4. Thermal Management:

    • Monitor the junction temperature (TJ) to ensure it stays within safe operating limits.
    • Use thermal paste between the device and the heatsink to improve thermal conductivity.
  5. Surge Currents:

    • Be cautious of surge currents during switching operations, as they can exceed the continuous current rating.
    • Design the circuit to handle these surges without exceeding the pulse current rating.
  6. Storage and Operation:

    • Store the device in a dry, cool environment to prevent moisture damage.
    • Operate the device within the specified temperature ranges to ensure reliability and longevity.
  7. Safety Precautions:

    • Always follow safety guidelines when working with high-voltage and high-current circuits.
    • Use appropriate protective equipment and grounding techniques to prevent electrical shock.
(For reference only)