Specifications
SKU: 11646032
Parameter | Symbol | Min | Typ | Max | Unit | Conditions |
---|---|---|---|---|---|---|
Forward Voltage | VF | 1.2 | - | 1.6 | V | IF = 20 mA |
Reverse Voltage | VR | - | - | 5 | V | |
Forward Current | IF | - | - | 50 | mA | |
Peak Forward Current | IF(s) | - | - | 150 | mA | t = 10 ms, duty cycle ≤ 1% |
Reverse Current | IR | - | - | 100 | nA | VR = 5 V |
CTR (Current Transfer Ratio) | CTR | 100 | 300 | 500 | % | IF = 5 mA, VCE = 5 V |
Collector-Emitter Voltage | VCE | - | - | 30 | V | |
Collector Current | IC | - | - | 15 | mA | |
Storage Temperature | TSTG | -40 | - | 105 | °C | |
Operating Temperature | TA | -40 | - | 105 | °C |
Instructions for Use:
Forward Voltage (VF):
- Ensure the forward voltage does not exceed 1.6V when operating at 20mA to avoid damaging the device.
Reverse Voltage (VR):
- The device can withstand up to 5V in reverse bias without damage.
Forward Current (IF):
- Do not exceed 50mA of continuous forward current to prevent overheating and potential failure.
Peak Forward Current (IF(s)):
- For short pulses, the peak forward current can be as high as 150mA, but ensure the pulse duration is limited to 10ms with a duty cycle of 1% or less.
Reverse Current (IR):
- The reverse leakage current should not exceed 100nA at 5V reverse voltage.
CTR (Current Transfer Ratio):
- The CTR ranges from 100% to 500% at a forward current of 5mA and a collector-emitter voltage of 5V. This indicates the efficiency of current transfer from the input to the output.
Collector-Emitter Voltage (VCE):
- The maximum collector-emitter voltage is 30V. Exceeding this can cause breakdown and damage to the device.
Collector Current (IC):
- The maximum collector current is 15mA. Higher currents can lead to overheating and failure.
Storage Temperature (TSTG):
- Store the device between -40°C and 105°C to ensure reliability and performance.
Operating Temperature (TA):
- The device can operate within the temperature range of -40°C to 105°C. Ensure adequate cooling if operating near the upper limit to prevent thermal runaway.
Additional Notes:
- Always use appropriate heat sinks or cooling mechanisms if the device is expected to operate at high currents or temperatures.
- Ensure proper PCB layout to minimize noise and interference.
- Follow ESD (Electrostatic Discharge) precautions during handling and installation to avoid damage to the device.