Specifications
SKU: 11648181
Parameter | Symbol | Min | Typ | Max | Unit | Condition |
---|---|---|---|---|---|---|
Forward Voltage | VF | - | 1.2 | 1.8 | V | IF = 10 mA |
Reverse Voltage | VR | - | - | 5 | V | IR = 5 mA |
Forward Current | IF | - | - | 50 | mA | Continuous |
Peak Forward Current | IFM | - | - | 100 | mA | t = 1 ms, repetitive |
Output Collector-Emitter Voltage | VCEO | - | - | 30 | V | IC = 50 mA, T_A = 25°C |
Output Collector Current | IC | - | 50 | 100 | mA | VCE = 5 V, IF = 5 mA |
Output Turn-On Time | tON | - | 2 | 5 | μs | IF = 5 mA, RL = 100 Ω, VCC = 5 V |
Output Turn-Off Time | tOFF | - | 2 | 5 | μs | IF = 5 mA, RL = 100 Ω, VCC = 5 V |
Isolation Voltage | VIORM | - | - | 2500 | Vrms | 1 minute, I_F = 0 mA |
Operating Temperature | TOPR | -40 | - | 85 | °C | |
Storage Temperature | TSTG | -55 | - | 125 | °C |
Instructions for Use:
Forward Current (IF):
- Ensure the forward current does not exceed 50 mA continuously.
- For peak applications, do not exceed 100 mA for more than 1 ms repetitively.
Output Collector-Emitter Voltage (VCEO):
- The maximum output collector-emitter voltage is 30 V. Ensure that the load does not cause this voltage to be exceeded.
Output Collector Current (IC):
- The typical output collector current is 50 mA, with a maximum of 100 mA under specified conditions.
Turn-On and Turn-Off Times:
- The typical turn-on and turn-off times are 2 μs, with a maximum of 5 μs. These values are based on specific test conditions (IF = 5 mA, RL = 100 Ω, VCC = 5 V).
Isolation Voltage:
- The device can withstand an isolation voltage of up to 2500 Vrms for 1 minute without damage.
Temperature Considerations:
- The operating temperature range is from -40°C to 85°C.
- The storage temperature range is from -55°C to 125°C.
Mounting and Handling:
- Handle the device with care to avoid mechanical stress.
- Follow proper soldering procedures to ensure reliable connections.
Electrostatic Discharge (ESD) Protection:
- Use appropriate ESD protection measures during handling and assembly to prevent damage to the device.
Circuit Design:
- Ensure that the circuit design includes necessary protection components such as current-limiting resistors and flyback diodes if required.
Compliance:
- Verify that the application complies with relevant safety and regulatory standards.