Share:


TLP571

Specifications

SKU: 11648181

BUY TLP571 https://www.utsource.net/itm/p/11648181.html

Parameter Symbol Min Typ Max Unit Condition
Forward Voltage VF - 1.2 1.8 V IF = 10 mA
Reverse Voltage VR - - 5 V IR = 5 mA
Forward Current IF - - 50 mA Continuous
Peak Forward Current IFM - - 100 mA t = 1 ms, repetitive
Output Collector-Emitter Voltage VCEO - - 30 V IC = 50 mA, T_A = 25°C
Output Collector Current IC - 50 100 mA VCE = 5 V, IF = 5 mA
Output Turn-On Time tON - 2 5 μs IF = 5 mA, RL = 100 Ω, VCC = 5 V
Output Turn-Off Time tOFF - 2 5 μs IF = 5 mA, RL = 100 Ω, VCC = 5 V
Isolation Voltage VIORM - - 2500 Vrms 1 minute, I_F = 0 mA
Operating Temperature TOPR -40 - 85 °C
Storage Temperature TSTG -55 - 125 °C

Instructions for Use:

  1. Forward Current (IF):

    • Ensure the forward current does not exceed 50 mA continuously.
    • For peak applications, do not exceed 100 mA for more than 1 ms repetitively.
  2. Output Collector-Emitter Voltage (VCEO):

    • The maximum output collector-emitter voltage is 30 V. Ensure that the load does not cause this voltage to be exceeded.
  3. Output Collector Current (IC):

    • The typical output collector current is 50 mA, with a maximum of 100 mA under specified conditions.
  4. Turn-On and Turn-Off Times:

    • The typical turn-on and turn-off times are 2 μs, with a maximum of 5 μs. These values are based on specific test conditions (IF = 5 mA, RL = 100 Ω, VCC = 5 V).
  5. Isolation Voltage:

    • The device can withstand an isolation voltage of up to 2500 Vrms for 1 minute without damage.
  6. Temperature Considerations:

    • The operating temperature range is from -40°C to 85°C.
    • The storage temperature range is from -55°C to 125°C.
  7. Mounting and Handling:

    • Handle the device with care to avoid mechanical stress.
    • Follow proper soldering procedures to ensure reliable connections.
  8. Electrostatic Discharge (ESD) Protection:

    • Use appropriate ESD protection measures during handling and assembly to prevent damage to the device.
  9. Circuit Design:

    • Ensure that the circuit design includes necessary protection components such as current-limiting resistors and flyback diodes if required.
  10. Compliance:

    • Verify that the application complies with relevant safety and regulatory standards.
(For reference only)

 Inquiry - TLP571