Specifications
SKU: 11654087
Parameter | Symbol | Conditions | Min | Typ | Max | Unit |
---|---|---|---|---|---|---|
Supply Voltage | VDD | - | 1.65 | - | 3.6 | V |
Quiescent Current | IQ | All switches off, VDD = 2.5V | - | 0.8 | - | μA |
On-State Resistance | RON | VDD = 2.5V, VIN = 0V to VDD | 4 | - | 7 | Ω |
Off-State Leakage Current | IOFF | VDD = 2.5V, VIN = 0V to VDD | - | 1 | - | nA |
Input Signal Range | VIN | - | 0 | - | VDD | V |
Switching Time (On) | tON | VDD = 2.5V, VIN = 0V to VDD | - | 0.5 | - | μs |
Switching Time (Off) | tOFF | VDD = 2.5V, VIN = 0V to VDD | - | 0.5 | - | μs |
Operating Temperature | TOP | - | -40 | - | 85 | °C |
Storage Temperature | TSTG | - | -65 | - | 150 | °C |
Instructions for Use:
Power Supply:
- Ensure that the supply voltage (VDD) is within the range of 1.65V to 3.6V.
- Connect the VDD pin to the power supply and GND to ground.
Signal Connections:
- Connect the input signals to the appropriate channels (IN1, IN2, IN3).
- Connect the output signals to the common output (OUT).
Control Signals:
- Use the control inputs (S0, S1, S2) to select the desired channel. The control signals should be logic levels compatible with the supply voltage.
- The truth table for the control inputs is as follows:
- S2 S1 S0 | Channel
- 0 0 0 | OFF
- 0 0 1 | IN1
- 0 1 0 | IN2
- 0 1 1 | IN3
Quiescent Current:
- The quiescent current (IQ) is typically 0.8 μA when all switches are off. This should be considered in low-power applications.
On-State Resistance:
- The on-state resistance (RON) is between 4 Ω and 7 Ω at VDD = 2.5V. This affects the signal integrity and power consumption when the switch is on.
Off-State Leakage Current:
- The off-state leakage current (IOFF) is typically 1 nA. This is important for applications where minimal leakage is required.
Switching Times:
- The switching times (tON and tOFF) are both typically 0.5 μs. This is useful for high-speed switching applications.
Temperature Considerations:
- The operating temperature range is from -40°C to 85°C.
- The storage temperature range is from -65°C to 150°C.
Handling and Storage:
- Store the device in a dry environment to prevent moisture damage.
- Handle the device with care to avoid static discharge, which can damage the internal components.
Testing:
- Before integrating the device into a circuit, test it with a simple setup to ensure proper functionality.
- Use a multimeter to check the continuity and resistance values when the switch is on and off.
Inquiry - ADG733BRUZ