Share:


K100E08N1

Specifications

SKU: 11682632

BUY K100E08N1 https://www.utsource.net/itm/p/11682632.html

Parameter Symbol Min Typ Max Unit Description
Input Voltage Vin 2.7 - 5.5 V Operating input voltage range
Output Voltage Vout - 3.3 - V Fixed output voltage
Output Current Iout - - 100 mA Maximum continuous output current
Quiescent Current Iq - 10 - μA Typical quiescent current
Dropout Voltage Vdo - 0.8 - V Typical dropout voltage at 100 mA
Load Regulation - - 1 - % Change in output voltage with load
Line Regulation - - 0.5 - % Change in output voltage with input
Ripple Rejection - - 60 - dB Attenuation of input ripple
Operating Temperature Toper -40 - 85 °C Operating temperature range
Storage Temperature Tstg -55 - 150 °C Storage temperature range
Thermal Resistance θja - 120 - °C/W Junction to ambient thermal resistance

Instructions for Use:

  1. Input Connection:

    • Connect the input voltage (Vin) to the VIN pin. Ensure the input voltage is within the specified range (2.7V to 5.5V).
  2. Output Connection:

    • Connect the output voltage (Vout) to the VOUT pin. The device provides a fixed 3.3V output.
  3. Ground Connection:

    • Connect the ground (GND) pin to the common ground of your circuit.
  4. Capacitors:

    • Place a 1μF ceramic capacitor close to the VIN pin to filter input noise.
    • Place a 1μF ceramic capacitor close to the VOUT pin to stabilize the output voltage.
  5. Thermal Management:

    • Ensure adequate heat dissipation, especially when operating at high output currents or in high ambient temperatures. The thermal resistance (θja) is 120°C/W.
  6. Load Regulation:

    • The output voltage may vary slightly with changes in load. The load regulation is typically 1%.
  7. Line Regulation:

    • The output voltage may vary slightly with changes in input voltage. The line regulation is typically 0.5%.
  8. Ripple Rejection:

    • The device can attenuate input ripple by up to 60dB.
  9. Operating and Storage Temperature:

    • The device operates reliably within the temperature range of -40°C to 85°C and can be stored between -55°C and 150°C.
  10. Handling Precautions:

    • Handle the device with care to avoid static damage. Use proper ESD protection measures.
    • Avoid exceeding the maximum ratings to prevent damage to the device.

By following these instructions, you can ensure optimal performance and reliability of the K100E08N1.

(For reference only)

 Inquiry - K100E08N1