Specifications
SKU: 11708805
Parameter | Symbol | Min | Typical | Max | Unit | Condition |
---|---|---|---|---|---|---|
Drain-Source Voltage | VDS | - | 500 | - | V | @ Tj = 25°C |
Gate-Source Voltage | VGS | -15 | - | 15 | V | |
Continuous Drain Current | ID | - | 13 | - | A | @ TC = 25°C |
Pulse Drain Current | IDpeak | - | 40 | - | A | tp = 10 μs, f ≤ 100 Hz |
Total Power Dissipation | PTOT | - | 130 | - | W | @ TC = 25°C |
Junction Temperature | Tj | - | - | 175 | °C | |
Storage Temperature | Tstg | -65 | - | 150 | °C |
Instructions for Use:
Handling Precautions:
- Handle the TSF13N50M with care to avoid damage to the leads and body.
- Use proper ESD (Electrostatic Discharge) protection when handling the device.
Mounting:
- Ensure that the mounting surface is clean and flat.
- Use thermal paste or a thermal pad to improve heat dissipation.
- Torque the screws to the recommended specifications to ensure good thermal contact.
Soldering:
- Preheat the PCB to 100-120°C before soldering.
- Use a soldering iron with a temperature setting between 260-300°C.
- Do not exceed a soldering time of 10 seconds per lead.
- Allow the device to cool naturally after soldering.
Operating Conditions:
- Ensure that the operating voltage does not exceed the maximum rated drain-source voltage (VDS).
- Keep the junction temperature within the specified range to avoid thermal damage.
- Use appropriate heatsinking to manage power dissipation.
Testing:
- Perform initial testing at room temperature to verify functionality.
- Gradually increase the load and monitor the device’s performance and temperature.
- Use a thermal imaging camera to check for hotspots during operation.
Storage:
- Store the TSF13N50M in a dry, cool place away from direct sunlight.
- Avoid exposure to high humidity and corrosive environments.
Safety:
- Always follow safety guidelines when working with high voltages and currents.
- Use appropriate personal protective equipment (PPE) as necessary.
Inquiry - TSF13N50M