Specifications
SKU: 11720193
Parameter | Symbol | Min | Typ | Max | Unit | Conditions/Notes |
---|---|---|---|---|---|---|
Forward Voltage | VF | - | 1.2 | 1.8 | V | IF = 20 mA, TJ = 25°C |
Reverse Voltage | VR | - | - | 5 | V | VR applied to the LED |
Forward Current | IF | - | 20 | 50 | mA | Continuous |
Peak Forward Current | IF(P) | - | - | 150 | mA | Pulse width ≤ 1 ms, duty cycle ≤ 2% |
Output Current | IC | 0.5 | 1.6 | 5 | mA | VCE(SAT) = 0.4 V, RL = 1 kΩ, IF = 20 mA, TJ = 25°C |
Collector-Emitter Saturation Voltage | VCE(SAT) | - | 0.4 | 0.7 | V | IC = 5 mA, IF = 20 mA, TJ = 25°C |
Isolation Voltage | VIORM | - | - | 5000 | Vrms | 1 minute, 50/60 Hz |
Storage Temperature | TSTG | -40 | - | 125 | °C | |
Operating Temperature | TJ | -40 | - | 125 | °C | Junction temperature |
Thermal Resistance | θJA | - | 120 | - | °C/W | Junction to ambient |
Instructions:
Power Supply:
- Ensure that the forward voltage (VF) is within the specified range when driving the LED.
- The reverse voltage (VR) should not exceed 5V to prevent damage to the LED.
Current Limiting:
- Use a current-limiting resistor to ensure the forward current (IF) does not exceed 50 mA continuously.
- For peak applications, do not exceed 150 mA with pulse widths ≤ 1 ms and duty cycles ≤ 2%.
Output Configuration:
- The output current (IC) should be within the range of 0.5 to 5 mA for reliable operation.
- Ensure the collector-emitter saturation voltage (VCE(SAT)) is maintained below 0.7V for optimal performance.
Isolation:
- The device provides an isolation voltage of up to 5000 Vrms for 1 minute at 50/60 Hz. Ensure this is not exceeded to avoid electrical breakdown.
Temperature Management:
- Operate the device within the specified storage and operating temperature ranges to ensure reliability and longevity.
- Consider thermal management solutions if the junction temperature (TJ) approaches the upper limit of 125°C.
Handling:
- Handle the device with care to avoid static discharge and physical damage.
- Follow proper soldering techniques and avoid excessive heat during assembly.
Testing:
- Before integrating the HCPL-316J-000E into your design, perform thorough testing under the specified conditions to ensure it meets your application requirements.