Specifications
SKU: 11720534
Parameter | Symbol | Min | Typ | Max | Unit | Notes |
---|---|---|---|---|---|---|
Drain-Source Voltage | VDSS | - | - | 600 | V | |
Gate-Source Voltage | VGS | -20 | - | 20 | V | |
Continuous Drain Current | ID | - | 16 | - | A | @ Tc = 25°C |
Pulse Drain Current | Ipp | - | 48 | - | A | @ Tc = 25°C, 10 ms, 1% Duty Cycle |
Power Dissipation | PD | - | - | 130 | W | @ Tc = 25°C |
Junction Temperature | TJ | -55 | - | 150 | °C | |
Storage Temperature | Tstg | -55 | - | 150 | °C | |
Thermal Resistance | RθJC | - | 0.75 | - | °C/W | Junction to Case |
Total Gate Charge | Qg | - | 130 | - | nC | @ VDS = 400V, ID = 10A, VGS = 15V |
Input Capacitance | Ciss | - | 2900 | - | pF | @ VDS = 400V, f = 1 MHz |
Output Capacitance | Coss | - | 650 | - | pF | @ VDS = 400V, f = 1 MHz |
Reverse Transfer Capacitance | Crss | - | 650 | - | pF | @ VDS = 400V, f = 1 MHz |
Instructions for Use:
Handling Precautions:
- Handle the P16NE06 with care to avoid damage to the pins and the device.
- Use proper ESD (Electrostatic Discharge) protection when handling the device.
Mounting:
- Ensure that the device is mounted on a heatsink to dissipate heat effectively, especially when operating at high power levels.
- Use thermal compound between the device and the heatsink to improve thermal conductivity.
Biasing:
- Apply the gate-source voltage (VGS) within the specified range (-20V to +20V).
- Ensure that the drain-source voltage (VDS) does not exceed 600V.
Current Handling:
- The continuous drain current (ID) should not exceed 16A at a case temperature of 25°C.
- For pulse applications, the peak drain current (Ipp) can be up to 48A, but ensure the duty cycle is 1% or less and the pulse duration is 10 ms or less.
Thermal Management:
- Monitor the junction temperature (TJ) to ensure it stays within the operational range (-55°C to 150°C).
- Use the thermal resistance (RθJC) value to calculate the required heatsink size for your application.
Storage:
- Store the device in a dry, cool place within the storage temperature range (-55°C to 150°C).
Testing:
- When testing the device, use appropriate test equipment and follow safety guidelines to prevent damage to the device or injury.
Documentation:
- Refer to the datasheet for more detailed information and specific application notes.
Inquiry - P16NE06