Specifications
SKU: 11723162
Parameter | Symbol | Min | Typ | Max | Unit | Notes |
---|---|---|---|---|---|---|
Operating Voltage | Voper | 2.7 | - | 5.5 | V | |
Breakdown Voltage | Vbr | 3.3 | - | - | V | |
Clamping Voltage | Vc | - | 4.9 | - | V | @ Ipp = 1A |
Peak Pulse Current | Ipp | - | - | 1 | A | 8/20 μs waveform |
Reverse Leakage Current | Irl | - | 1 | 10 | μA | @ Vrwm = 3.3V |
Capacitance | C | - | 10 | - | pF | @ Vrwm = 0V, f = 1 MHz |
Response Time | tr | - | 1 | - | ns | |
Operating Temperature | Topr | -40 | - | 85 | °C | |
Storage Temperature | Tstg | -65 | - | 150 | °C |
Instructions for Use:
Mounting:
- Ensure the device is mounted with adequate clearance to prevent short circuits.
- Use recommended PCB layout guidelines to ensure proper thermal dissipation.
Handling:
- Handle the device with ESD protection measures to avoid damage.
- Avoid applying mechanical stress to the leads or body of the device.
Electrical Connections:
- Connect the device in parallel with the circuit it is protecting.
- Ensure that the polarity is correct if the device is not bidirectional.
Thermal Management:
- Ensure adequate cooling if the device is expected to handle high pulse currents.
- Consider using a heatsink if necessary.
Testing:
- Test the device under controlled conditions to verify its performance.
- Use appropriate test equipment to measure parameters such as clamping voltage and leakage current.
Storage:
- Store the device in a dry, cool place away from direct sunlight.
- Follow recommended storage temperature limits to ensure long-term reliability.
Compliance:
- Ensure that the device meets all relevant safety and regulatory standards for the intended application.
Inquiry - PESD3V3L1UL315