Share:


EPF10K20TC144-4

Specifications

SKU: 11737713

BUY EPF10K20TC144-4 https://www.utsource.net/itm/p/11737713.html

Parameter Description Value
Device Type Type of device CPLD (Complex Programmable Logic Device)
Family Family of the device FLEX 10K
Part Number Specific part number EPF10K20TC144-4
Package Package type TQFP (Thin Quad Flat Package)
Pins Number of pins 144
Speed Grade Speed grade of the device -4 (fastest for this family)
Logic Cells Number of logic cells 20,000
I/O Pins Number of I/O pins 132
Internal Memory (bits) Internal memory size 576 bits
Max. Operating Frequency Maximum operating frequency 181 MHz
Supply Voltage (Vcc) Supply voltage range 3.3V ± 5%
Standby Current Current consumption in standby mode 50 μA
Active Power Power consumption in active mode 1.5 W (typical)
Temperature Range Operating temperature range -40°C to +85°C
Configuration Method Method for configuring the device JTAG, AS (Active Serial), PS (Passive Serial)
Programming Voltage Voltage required for programming 3.3V
Programming Time Typical time required for programming 20 ms (for full configuration)
ESD Protection Electrostatic discharge protection 2000 V (HBM)
RoHS Compliance Compliance with Restriction of Hazardous Substances Directive Yes

Instructions for Use

  1. Power Supply:

    • Ensure that the supply voltage (Vcc) is within the specified range of 3.3V ± 5%.
    • Connect the ground (GND) pin to a stable ground reference.
  2. Configuration:

    • Use one of the supported configuration methods: JTAG, Active Serial (AS), or Passive Serial (PS).
    • For JTAG, connect the TDI, TDO, TCK, and TMS pins to the JTAG interface.
    • For AS, connect the AS_DATA, AS_CLK, and AS_DCLK pins to the configuration source.
    • For PS, connect the PS_DATA and PS_CLK pins to the configuration source.
  3. Programming:

    • Use a compatible programmer or software to load the configuration file.
    • Ensure the programming voltage is set to 3.3V.
    • The typical programming time is 20 ms for a full configuration.
  4. Operating Conditions:

    • Operate the device within the specified temperature range of -40°C to +85°C.
    • Avoid exceeding the maximum operating frequency of 181 MHz to prevent performance issues.
  5. Handling:

    • Handle the device with care to avoid ESD damage.
    • Store the device in an ESD-protected environment when not in use.
  6. Testing:

    • After programming, verify the functionality of the device using appropriate test vectors.
    • Monitor power consumption and ensure it does not exceed the specified active power of 1.5 W (typical).
  7. Documentation: