Specifications
SKU: 11743078
Parameter | Symbol | Min | Typ | Max | Unit |
---|---|---|---|---|---|
Input Voltage | VIN | 2.7 | - | 5.5 | V |
Output Current | IOUT | - | 3.0 | 6.0 | A |
Quiescent Current | IQ | - | 1.2 | 2.0 | mA |
Shutdown Current | ISD | - | 0.1 | 0.5 | μA |
Output Voltage | VOUT | - | 3.3 | - | V |
Dropout Voltage | VDROPOUT | - | 0.2 | 0.5 | V |
Operating Temperature | TOPR | -40 | - | 125 | °C |
Storage Temperature | TSTG | -65 | - | 150 | °C |
Thermal Resistance | RθJA | - | 50 | - | °C/W |
Instructions for Using KTD600K-Y-U/P
Input Voltage (VIN):
- Ensure the input voltage is within the range of 2.7V to 5.5V to avoid damage to the device.
Output Current (IOUT):
- The device can provide a typical output current of 3.0A, with a maximum of 6.0A. Do not exceed the maximum output current to prevent overheating or damage.
Quiescent Current (IQ):
- The quiescent current is typically 1.2mA and should not exceed 2.0mA. This is the current consumed by the device when it is active but not providing any load current.
Shutdown Current (ISD):
- When the device is in shutdown mode, the current consumption should be between 0.1μA and 0.5μA. Use the shutdown pin to control this state.
Output Voltage (VOUT):
- The output voltage is typically 3.3V. Ensure that the load connected to the output can operate within this voltage range.
Dropout Voltage (VDROPOUT):
- The dropout voltage is the difference between the input and output voltages when the device is operating at its maximum load. It is typically 0.2V and should not exceed 0.5V.
Operating Temperature (TOPR):
- The device is designed to operate within a temperature range of -40°C to 125°C. Ensure that the ambient temperature does not exceed these limits.
Storage Temperature (TSTG):
- The device can be stored at temperatures ranging from -65°C to 150°C. However, avoid prolonged exposure to extreme temperatures.
Thermal Resistance (RθJA):
- The thermal resistance from junction to ambient is typically 50°C/W. Ensure adequate heat dissipation to maintain the device within safe operating temperatures, especially under high load conditions.
Handling Precautions:
- Handle the device with care to avoid static discharge, which can damage sensitive components.
- Follow proper soldering techniques to ensure reliable connections and avoid thermal shock.
- Use appropriate decoupling capacitors to stabilize the input and output voltages and reduce noise.
Application Notes:
- Refer to the datasheet and application notes for detailed information on circuit design, layout guidelines, and specific use cases.
By following these instructions, you can ensure optimal performance and reliability of the KTD600K-Y-U/P device in your application.
(For reference only)Inquiry - KTD600K-Y-U/P