Share:


BTB12-600CW

Specifications

SKU: 11743102

BUY BTB12-600CW https://www.utsource.net/itm/p/11743102.html

Parameter Symbol Value Unit
Maximum Repetitive Peak Off-State Voltage VDRM 600 V
Maximum Repetitive Peak On-State Voltage VRRM 600 V
Maximum RMS On-State Current (100% duty cycle) IT(RMS) 12 A
Maximum Non-Repetitive Peak On-State Current (8.3 ms, sin 50 Hz) IWM 72 A
Maximum Gate Trigger Current (TJ = 25°C) IG(T) 100 mA
Maximum Gate Trigger Voltage (TJ = 25°C) VG(T) 2.0 V
Maximum Gate Trigger Current (TJ = 100°C) IG(T) 200 mA
Maximum Gate Trigger Voltage (TJ = 100°C) VG(T) 2.5 V
Holding Current IH 10 mA
Junction Temperature TJ -40 to +125 °C
Storage Temperature TSTG -40 to +125 °C

Instructions for Use:

  1. Mounting and Handling:

    • Ensure that the device is mounted on a suitable heatsink to maintain junction temperature within specified limits.
    • Handle the device with care to avoid mechanical damage.
  2. Electrical Connections:

    • Connect the anode and cathode terminals correctly to avoid reverse polarity which can lead to device failure.
    • The gate terminal should be connected to the control circuit with appropriate current limiting resistors to prevent excessive gate current.
  3. Thermal Management:

    • Ensure adequate cooling to keep the junction temperature within the specified range. Excessive temperature can reduce the life of the device and cause immediate failure.
    • Use thermal paste between the device and heatsink to improve heat transfer.
  4. Gate Triggering:

    • Apply a gate trigger pulse with sufficient amplitude and duration to ensure reliable turn-on. The recommended gate trigger current is at least 100 mA for TJ = 25°C and 200 mA for TJ = 100°C.
    • Ensure the gate trigger voltage is within the specified range to avoid overvoltage conditions.
  5. Operating Conditions:

    • Do not exceed the maximum ratings for voltage, current, and temperature.
    • Avoid operating the device in conditions where it may experience excessive thermal cycling or mechanical stress.
  6. Storage:

    • Store the device in a dry, cool place away from direct sunlight and sources of heat.
    • Follow ESD (Electrostatic Discharge) precautions to prevent damage to the device.
  7. Testing:

    • Before installation, test the device using a suitable tester to ensure it meets the specified parameters.
    • Regularly inspect the device and connections for signs of wear or damage.

By following these guidelines, you can ensure reliable and safe operation of the BTB12-600CW triac.

(For reference only)

 Inquiry - BTB12-600CW