Share:


ADS1115BQDGSRQ1

Specifications

SKU: 11750117

BUY ADS1115BQDGSRQ1 https://www.utsource.net/itm/p/11750117.html

Parameter Symbol Min Typical Max Unit Description
Supply Voltage VDD 2.0 - 5.5 V Operating supply voltage range
Input Voltage Range VIN -0.3 - VDD+0.3 V Maximum input voltage range
Conversion Time (12-bit) tCONV - 780 - μs Typical conversion time for 12-bit resolution
Data Output Rate DR 0.5 - 860 SPS Data output rate
Power Consumption IDD 150 - 1000 μA Quiescent current
Input Bias Current IB - 10 - nA Input bias current
Differential Input Range VDIFF - 4.096 - V Differential input voltage range
Common-Mode Rejection Ratio CMRR 90 - 100 dB Common-mode rejection ratio
Temperature Range Toper -40 - 85 °C Operating temperature range
Package Type - - - - QFN-10 Package type

Instructions for Using ADS1115BQDGSRQ1

  1. Power Supply:

    • Connect the VDD pin to a power supply within the range of 2.0V to 5.5V.
    • Connect the GND pin to the ground.
  2. Input Configuration:

    • Configure the multiplexer (MUX) to select the desired input channels (single-ended or differential).
    • Ensure that the input voltages do not exceed the input voltage range of -0.3V to VDD + 0.3V.
  3. Data Conversion:

    • Set the data output rate (DR) according to your application requirements.
    • Start a conversion by writing to the configuration register.
    • Read the conversion result from the conversion register.
  4. Communication:

    • Use I2C communication to interface with the ADS1115.
    • The default I2C address is 0x48, but it can be changed by connecting the ADR pin to GND, VDD, or a floating state.
  5. Configuration Register:

    • Write to the configuration register to set parameters such as MUX, gain, data rate, and operating mode.
    • The configuration register is 16 bits long.
  6. Conversion Register:

    • Read the 16-bit conversion result from the conversion register.
    • The result is left-justified for 12-bit resolution.
  7. Operating Mode:

    • Choose between continuous conversion mode or single-shot mode.
    • In single-shot mode, the device powers down after each conversion to save power.
  8. Temperature Considerations:

    • Ensure that the device operates within the temperature range of -40°C to 85°C.
    • For extended temperature ranges, consult the datasheet for additional specifications.
  9. Power Management:

    • To reduce power consumption, use the power-down mode when conversions are not required.
    • The device automatically enters power-down mode in single-shot mode after a conversion.
  10. Handling and Storage:

    • Handle the device with care to avoid static discharge.
    • Store the device in a dry, cool place to prevent damage.

For more detailed information, refer to the official datasheet of the ADS1115BQDGSRQ1.

(For reference only)

 Inquiry - ADS1115BQDGSRQ1