Specifications
SKU: 11756253
Parameter | Symbol | Min | Typ | Max | Unit |
---|---|---|---|---|---|
Supply Voltage | Vcc | 4.5 | - | 30 | V |
Continuous Collector Current | Ic | - | 1.5 | 3.0 | A |
Peak Collector Current | Icm | - | - | 5.0 | A |
Collector-Emitter Saturation Voltage | Vce(sat) | 0.7 | 1.2 | 1.8 | V |
Base-Emitter Saturation Voltage | Vbe(sat) | 1.2 | 1.8 | 2.5 | V |
Storage Temperature | Tstg | -40 | - | 150 | °C |
Operating Junction Temperature | Tj | -40 | - | 150 | °C |
Instructions for BD681 DOMESTIC TO-126
Power Supply:
- Ensure the supply voltage (Vcc) is within the range of 4.5V to 30V.
Current Handling:
- The continuous collector current (Ic) should not exceed 3.0A.
- For short durations, the peak collector current (Icm) can be up to 5.0A.
Voltage Ratings:
- The collector-emitter saturation voltage (Vce(sat)) should be between 0.7V and 1.8V.
- The base-emitter saturation voltage (Vbe(sat)) should be between 1.2V and 2.5V.
Temperature Considerations:
- Store the device in an environment where the temperature ranges from -40°C to 150°C.
- Ensure the operating junction temperature (Tj) does not exceed 150°C.
Mounting:
- Use appropriate heat sinks if the device will be operating at high currents or temperatures.
- Ensure proper mechanical mounting to avoid stress on the leads.
Handling:
- Handle the device with care to avoid static damage.
- Follow standard ESD (Electrostatic Discharge) precautions during handling and installation.
Testing:
- Before final assembly, test the device under typical operating conditions to ensure it meets the specified parameters.
Soldering:
- Use a controlled soldering process to avoid overheating the device.
- Soldering temperature should not exceed 260°C for more than 10 seconds.
Storage:
- Store the device in a dry, cool place to prevent moisture damage.
Compliance:
- Ensure that the device complies with all relevant safety and regulatory standards for your application.
Inquiry - BD681 DOMESTIC TO-126